Chapter 2
Basic Operation
2.2
Using the FUNCTION Button
2.2
Using the FUNCTION Button
This section explains how to use the FUNCTION button of the controller enclosure.
The following settings can be performed by using the FUNCTION button:
Switching the Master CM to the other controller
•
For the two controllers in the ETERNUS DX, the controller through which the ETERNUS DX is set up and
operated is called the "Master CM", while the other controller is called the "Slave CM". The single-control-
ler type only has a "Master CM" controller.
•
Restoring the factory default settings (network environment settings and firewall settings) of the LAN ports
The following procedure explains how to use the FUNCTION button.
1
Remove the flange cover of the controller enclosure.
2
Change the status of the ETERNUS DX to maintenance status.
Use the pin to push down the FUNCTION button for three seconds.
The ETERNUS DX is in maintenance status when the MAINTENANCE LED is green.
FUJITSU Storage ETERNUS DX60 S3 Disk storage system Operation Guide (Basic)
Copyright 2014 FUJITSU LIMITED
38