7.30 Macro Protection

MENU 30:- Macro Protection
0=Off 1= On, 2= Rd Usr 3= Rd Fac 4= Wr Usr
This menu provides two functions
1) Enable and disable changes to the keyboard, Macro keys, pre-roll ...
2) Control access to the EEPROM and FACTORY setups
The addition of an EEPROM to the system allows the user to select between three different settings
as follows:
1) Current: destroyed when Read User or Read Factory are selected or a Hard Reset command.
2) User: selected by Read User or a hard reset command
3) Factory: selected by Read Factory
This Menu controls access to user settings and the EEPROM
0= Off
Macro's can be changed from the keyboard.
System Track Arm Keys may be changed from the keyboard
Pre/Post Roll May be changed from the keyboard
1= On
Macro's cannot be changed from the keyboard
System Track Arm Keys cannot be changed from the keyboard
Pre/Post Roll cannot be changed from the keyboard
2= Rd Usr
On exit from Setup the unit will read User Setup from EEPROM, the macro protection will default to 1=
On. This is activated on leaving setup.
3= Rd Factory
On exit from Setup the unit will read the Read Factory Setup from EPROM, the macro protection will
default to 1= On. This is activated on leaving setup.
4= Wr Usr
Setup the unit to work in your preferred manner then select to write current setup to EEPROM, the
macro protection will default to 1= On. This is activated on leaving setup and may take up to 20
seconds to compleat the write.
The following table shows how the memory's are initialised after a power-up reset or a hard reset.
Action
Power-On or
Reset Button
Hard Reset

7.301 Installing New Software

When new software is installed it may be necessary to initialise user setup in the EEPROM as follows:-
i)
Select the Macro protection Menu Setup | Root | Unit | Generic: menu 30:- Macro Protection
ii)
Depress the 3 key to select 3= Rd Fac.
iii)
Depress the Setup key twice to exit setup.
iv)
Depress the Setup key to Re-enter the macro protection menu, this should now be selected to