Recovery Function - APRILIA TUONO 1000 Workshop Manual

Hide thumbs Also See for TUONO 1000:
Table of Contents

Advertisement

TUONO 1000
7.1.6.

RECOVERY FUNCTION

In case the signal of the following sensors is interrupted, the control unit either sets a series of values to let the engine
work anyway or uses a different parameter. In any case, the instrument panel highlights that there is a fault.
Air temperature
Water temperature
Barometric pressure
TPS
Intake pressure
Stepper motor
18°C (64.4 °F)
88°C (190.4 °F)
In case the signal is lost the ECU sets the value of 88°C (190.4 °F), with
linear increase by 0.33°C/sec (32.6°F/sec) starting from air temperature
upon start-up.
On the instrument panel 135 (°C) flashes and the WARNING light turns on.
980 hPa
9.8°
Uses the value from the intake pressure sensor.
Values according to engine rpm and TPS are set (front and rear cylinder
intake pressure values are fixed and are not used for engine operation)
21