E LECTRICAL EQUIPMENT
OIL LEVEL INDICATOR UNIT
O I L LEVEL SENSOR INSPECTION
Disconnect the coupler and remove the sensor.
Lower the float fully until it will no longer go.
Measure the resistances between the terminals as
shown.
(-1
Terminal
(+)
Green/Red (+I to Black
Green (-) to Black
O I L LEVEL I N D ICATOR SWITCH
I NSPECTION
Connect the coupler and turn the ignition switch
ON. With the float raised fully, measure the resist
ance between the terminals.
Green/Red (+) to Black
(-1
NOTE:
Operate the turn signals to see that the bat
tery circuit is normal, then perform the fol
lowing inspection.
Raise and lower the float to make sure that the oil
level indicator lamp blinks.
NOTE:
Should the lamp fail to go on and go out as
the float is moved up and down, check for
loose connections and repeat the above proce
dure.
1 5 - 1 8
O I L LEVEL SENSOR
Resistance
5-15
n
00
340 .U approx.
176
HONDA
NHSO
GR EEN/RED
BLACK
±
4.5
.0 mm
1
0.0 4 in)
( 0. 18
±
O I L LAMP
Date of Issue: May, 1983
© HONDA MOTOR CO., LTD.
BLACK