Panasonic S-45PU1E5 Technical Data & Service Manual page 46

Inverter r410a
Table of Contents

Advertisement

1
Simultaneous (Double-Twin) -Type
1-1. Unit Specifi cations
Ceiling Type S-36PT1E5×4 / U-125PE1E8
INDOOR
PANEL
OUTDOOR
Branch pipe
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
CURRENT
INPUT POWER
C
ANNUAL CONSUMPTION
O
EER/EER CLASS
O
Pdsign
L
SEER
Erp
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
NOISE OUTDOOR
(H/L)
CAPACITY
CURRENT
INPUT POWER
H
COP/COP CLASS
E
Pdsign
A
Tbivalen
T
Erp
SCOP
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
NOISE OUTDOOR
(H/L)
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE ( MAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
I/D AIR
COOL
FLOW
HEAT
COOL
O/D AIR
FLOW
HEAT
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Operation
Condition
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
P
PIPE LENGTH RANGE
I
I/D&O/D HEIGHT DIRRERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1 In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2 If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6 SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
MODEL
S-36PT1E5×4
MODEL
MODEL
MODEL
ø, Hz
1ø 50Hz
V
220
kW
12.5
BTU/h
42700
A
0.33×4
W
31×4
TOTAL W
TOTAL W
4
TOTAL(W/W) 5/("A"~"G")
-
kW
-
(W/W)
-
kWh
-
-
%
-
dB-A
35/32/30
Power Level dB
53/50/46
dB-A
Power Level dB
kW
14.0
BTU/h
47800
A
0.33×4
W
31×4
TOTAL W
TOTAL(W/W) 5/("A"~"G")
-
kW
-
°C
-
(W/W)
-
kWh
-
-
%
-
dB-A
36/32/30
Power Level dB
54/50/47
dB-A
Power Level dB
0.33×4/31×4 0.32×4/31×4 0.32×4/31×4 10.0/6.200k
-
L/h(Pt/h)
7.9 (1.98×4)
Pa (mmAq)
3
3
m
/min (ft
/min)
12×4
3
3
m
/min (ft
/min)
12×4
m
3
/min (ft
3
/min)
3
3
m
/min (ft
/min)
210 (8-9/32)
910 (35-13/16)
680 (26-25/32)
21 (46)
24 (53)
11 (12)
Cool O.D(DBT)
18°C ~ 32°C
Heat O.D(DBT)
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
-
ISO5151 / EN14825
230
240
380
12.5
12.5
42700
42700
0.32×4
0.32×4
6.10
31×4
31×4
3.775k
-
3.900k
-
-
-
-
3.21
-
-
-
-
-
-
-
-
-
-
-
-
-
-
94
14.0
14.0
47800
47800
0.32×4
0.32×4
5.80
31×4
31×4
3.576k
-
3.700k
-
-
3.78
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
94
-
-
-
-
-
6.10/3.0k
-
40×4
(16.6)
-
(424)×4
(424)×4
130
110
R410A
280
985
780
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
5 ~ 75
(16.4 ~ 246.1)
50
(537.6)
20
(65.6)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-40
-
U-125PE1E8
-
3ø 50Hz
400
415
5.80
5.60
3.774k
3.772k
3.900k
3.900k
1950
-
3.21 / A
3.21
-
-
-
-
-
-
-
-
94
94
53/-
70/-
14000
5.50
5.30
3.575k
3.574k
3.700k
3.700k
3.78 / A
3.78
-
-
-
-
-
-
-
-
-
-
94
94
-
-
53/-
70/-
10.0/6.500k
10.0/6.750k
5.80/3.0k
5.60/3.0k
-
90×2
-
(4591)
(3885)
3.40k
(119.9)
1416 (55-3/4)
940 (37-1/32)
340 (13-13/32)
1556
1055
485
98
108
1 (2)
-15°C ~ 46°C
-20°C ~ 24°C
fl ared type, 5.0(16.4)
(49.2/98.4)
Min
Max
3.3
14.0
11300
47800
-
-
-
-
840
4.600k
-
-
3.93
3.04
-
-
4.1
16.0
54600
-
-
-
-
900
5.200k
4.56
3.08
-
-
/
/
/
/
/
/
/
/
/
~
~