Panasonic S-45PU1E5 Technical Data & Service Manual page 327

Inverter r410a
Table of Contents

Advertisement

P29 Lack of INV compressor wiring, INV compressor actuation failure
(including locked) due to DCCT failure
1.
Error Detection Method
Abnormal current is detected at DCCT before start-up.
Start-up failed during overcurrent and/or step-out detected.
Open-wire of compressor and/or backspin detected.
Secondary current is not detected during INV compressor is running.
2.
Error Diagnosis
1 Wiring
Disconnected parts, miswiring and/or poor connections (loose)
are observed in the connections of HIC PC board(s) that are
1-1
connected by wiring to a compressor. *1
Disconnected parts, miswiring and/or poor connections (loose)
are observed in the connections of outdoor board(s) that are
1-2
connected by wiring from the HIC PC board. *1
Disconnections and/or miswiring is observed in the connections
2
2-1
of the compressor terminals. *1
Compressor
wiring
Conditions such as burned terminal covers and/or discolored
2-2
terminals are observed at the connectors of the compressor
terminals. *1
The results of the pass/fail tests for the following HIC PC board
3 Check the
3-1
IPM show it to be outside the range of the resistance of a
HIC PC
conforming part.
boards
Replace the HIC PC board and operate the unit. (Apply putty
3-2
and screws must not be loose) Does it operate normally?
4
Check the
outdoor control
4-1
Replace the control PC board and operate the unit.
PC board
*1
Checking for looseness of compressor terminals by wiggling them has the adverse effect of loosening them, so do not do it.
Evaluate them by discoloration of wire insulation near the terminal.
HIC board IPM Pass/Fail Tests
Measure with an analog tester. (Set to the k ohm range)
Measure the board by itself. (Remove wires connected from other parts.)
Measure using IPM terminals.
Conforming part resistance value (measure with an analog tester)
Tester terminals
+
-
Resistance value (ohm)
Tester terminals
-
+
Resistance value (ohm)
Excepting the parts of "
value is "0 = short-circuit".
Tester terminals
+
-
Resistance value (ohm)
Tester terminals
-
+
Resistance value (ohm)
Excepting the parts of "
value is "0 = short-circuit".
P
U
V
1 k to 5 k
1 k to 5 k
1 k to 5 k 5 k to 10 k 100 k to
P
U
V
100 k to
100 k to
100 k to
100 k to
", it is acceptable if a small resistance value appears as a reference value unless the
HIC+
U
V
1 k to 10 k 1 k to 10 k 1 k to 10 k 5 k to 20 k 20 k to
HIC+
U
V
20 k to
20 k to
20 k to
20 k to
", it is acceptable if a small resistance value appears as a reference value unless the
W
NU
U
W
U
1 k to 5 k
W
HIC-
U
W
U
1 k to 10 k
5-55
Correct wiring
Yes
connections
No
1-2
Correct wiring
Yes
connections
No
2-1
Yes
Correct
No
2-2
Eliminate looseness
by changing the
Yes
terminals, or crimping
the terminals again.
No
3-1
Yes
Replace the HIC board
No
3-2
Yes
See what happens.
No
4-1
See what happens.
NU
V
W
100 k to
100 k to
100 k to
NU
V
W
1 k to 5 k
1 k to 5 k
HIC-
V
W
HIC+
20 k to
20 k to
20 k to
HIC-
V
W
1 k to 10 k
1 k to 10 k
5
P

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents