Sensor Temperature Display Function
(displayed regardless of whether unit
is operating or stopped)
The procedure below displays the sensor
temperatures from the remote controller, indoor unit,
and outdoor unit on the remote controller.
<Procedure>
1 Press and hold the
simultaneously for 4 seconds or longer.
2 The unit No. "X-X" (main unit No.), item code "XX"
(sensor address), and servicing monitor "
(sensor temperature) are displayed on the remote
controller LCD display. (See Fig. 7-4 at right.)
3 Press the temperature setting
buttons and select the item code to the address of
the sensor to monitor.
(For the relationships between the sensor
addresses and sensor types, refer to the table of
temperature sensors and addresses at below.)
4 If group control is in effect, press the
button to select the unit to monitor.
Press the temperature setting buttons to select the
item code to change.
5 Press the
controller display.
Indoor unit sensors
02
Intake temp.
03
E1
04
E2
05
E3
06
Discharge temp.
07
Discharge temp. setting
Position of indoor unit
08
electronic control valve
7
and
buttons
/
button to return to normal remote
Unit No.1 Unit No.2 Unit No.3 Unit No.4
"
1
5
Note:
The temperature display appears as "- - - -" for units
that are not connected.
*
If monitor mode is engaged while normal operation
is in progress, only the parts of the LCD display
shown in the figure will change. Other parts
continue to display the same information as during
normal operation.
Outdoor unit sensors
0A
2A
4A
0B
2B
4B
0C
2C
4C
0D
2D
4D
0E
2E
4E
0F
2F
4F
10
30
50
11
31
51
12
32
52
13
33
53
14
34
54
15
35
55
16
36
56
17
37
57
18
38
58
19
39
59
1A
3A
5A
1B
3B
5B
1C
3C
5C
1D
3D
5D
1E
3E
5E
1F
3F
5F
20
40
60
21
41
61
22
42
62
7-16
2
4
Fig. 7-4
6A
Discharge temp. 1
6B
Discharge temp. 2
6C
High-pressure sensor temp.
6D
Heat exchanger gas 1
6E
Heat exchanger liquid 1
6F
Heat exchanger gas 2
70
Heat exchanger liquid 2
71
Outdoor air temp.
72
73
For inspection
74
CT2
75
For inspection
76
For inspection
77
Discharge temp. 3
78
CT3
79
For inspection
7A
For inspection
7B
Heat exchanger gas 3
7C
Heat exchanger liquid 3
7D
Low-pressure sensor temp.
7E
Receiver temp.
7F
Oil 1
80
Oil 2
81
Oil 3
82
For inspection
3
CZ-RTC2