5-1.2 Creating A Security (Mirror) Array With New Drives - SOLTEK SL-75DRV3/75DRV3+ User Manual

Table of Contents

Advertisement

75DRV3/75DRV3+

5-1.2 Creating A Security (Mirror) Array With New Drives

FastTrak100-Lite on board permits only two drives to be used for a single
Mirroring array with FastBuild Utility.
1. Boot your system with FastTrak100-Lite Controller enabled by JP11
and your hard drive(s) connected to IDE3/IDE4. Suppose this is
the first time to create a Disk Array. The Promise BIOS on board with
FastBuild Utility built in will scan the IDE devices and display the result
as below:
FastTrak100-Lite (tm) BIOS Version 1.xx (Build xxxx)
(c) 1995-2000 Promise Technology, Inc. All Rights Reserved.
No array is defined...
Press <Ctrl-F> to enter FastBuild (tm) Utility
Or press <ESC> key to continue booting the system.
2. Press <Ctrl-F> keys to display the FastBuild (tm) Utility Main Menu.
3. Press "1" to display the Auto Setup Menu below. This is the fastest and
easiest method to create your first array.
FastBuild (tm) Utility 1.xx (c) 1995-2000 Promise Technology, Inc.
Optimize Array for:
Typical Application usage:
Mode ............................................... Stripe
Spare Drive .............................................0
Drives used in Array ................................1
Array Disk Capacity .........................38166
[ ] Up [ ] Down [ , , Space] Change Option
[Auto Setup Options Menu]
[Array Setup Configuration]
[Keys Available]
[ESC] Exit [Ctrl-Y] Save