5-2.13 Rebuilding A Mirroring Array - SOLTEK SL-75DRV3/75DRV3+ User Manual

Table of Contents

Advertisement

5-2.13 Rebuilding A Mirroring Array

The Rebuild Array <5> Menu option is necessary for recovering from an
error in a mirrored disk array. You will receive an error message when
booting your system from the FastTrak BIOS.
NOTE:
Drives MUST be replaced if they contain any physical errors.
Follow these steps BEFORE using the Rebuild Array menu option:
1. On bootup, the FastTrak100-Lite Startup BIOS will display an error
message identifying which drive has failed.
2. Press <Ctrl-F> keys to enter FastBuild Main Menu.
3. Select submenu Define Array <3>.
4. Select the failed array and identify the Channel and ID of the failed drive.
5. Power off and physically remove the failed drive.
6. Replace the drive with an identical model.
7. Reboot the system and enter the FastBuild Main Menu.
8. Select the <5> Rebuild Array option. The following screen will appear.
FastBuild (tm) Utility 1.xx (c) 1995-2000 Promise Technology, Ine.
Array No
Array 1
Array 1
Array 1
Array 1
[ ] Up [ ] Down
9. Highlight the array whose Status is "Critical".
10. Press [Enter]. The following screen will then appear (see next page).
[ Delete Array Menu ]
RAID Mode
Total Drv
Mirror
2
-------
--
-------
--
-------
--
[ Keys Available ]
[Esc] Exit
107
Chapter 5 RAID Controller
Capacity(MB)
Status
16126
Critical
--------
-------
--------
-------
--------
-------
[Del] Delete

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl-75drv3Sl-75drv3+

Table of Contents