Ram Clearing
All Memory Clear
RAM clearing the cash register erases all programming and totals. Use this program the first
time the cash register is programmed.
WARNING: This is a one time procedure. Do not repeat this procedure after the cash
register is programmed; it causes all programs and totals to be erased.
Follow this procedure to clear totals from memory:
1. Unplug the ECR.
2. Turn the control lock to the S position. (The S position is a hidden position one
3. Press and hold the CHARGE key on key board and plug the ECR into a power
4. When the buzzer beeps release the CHARGE key. Press the upper left key of the
5. When memory is cleared, the register prints a message "RAM ALL CLEAR OK!"
SAM4s ER-180T Operator's & Programming Manual v1.4
position clockwise from the PRG position.)
source.
keyboard, then the lower left key, then the upper right key, and finally press the lower
right key.
1
2
Memory is cleared and the default program is installed.
3
CHARGE
4
Getting Started 15