Ram Clearing
All Memory Clear
RAM clearing the cash register erases all programming and totals. Use this program the
first time the cash register is programmed.
WARNING: This is a one time procedure. Do not repeat this procedure after the cash
register is programmed; it causes all programs and totals to be erased.
Follow this procedure to clear totals from memory:
1. Unplug the ECR.
2. Press and hold the CHARGE key on key board and plug the ECR into a po
3. When the buzzer beeps release the CHARGE key. Press the upper left key
4. Display will show "= = = = = = = = = = = =" while proceeding.
5. When memory is cleared, the register prints a message "RAM ALL CLEAR
8 • Getting Started
wer source. Display show 'ALLCLEAr'.
of the keyboard, then the lower left key, then the upper right key, and finally
press the lower right key. Display will show "gOOd", if you press correct keys.
①
②
OK!" Memory is cleared and the default program is installed.
③
CHARGE
④
ER-180U