Christie CP2220 User Manual page 154

Hide thumbs Also See for CP2220:
Table of Contents

Advertisement

Section Appendix B: Serial API
LUT CLUT Control (LCT)(Continued)
Replace xxx with the channel number. Valid range is 101 - 164.
Cxxx
Select CUT for the current channel.
NONE
EXAMPLES:
(LCT+C108 "9x9x9") Use PCF file "9x9x9" on channel 108
(LCT+C108?) Get LUT-CLUT file name on channel 108
(LCT?L) List all entries of LUT-CLUT control
Link Decryptor Bypass (LDB)
Setting LD bypass to TRUE (1) will bypass the link decryptor (LD). Only use if marriage is broken and content being played is
not CineLink 2 encrypted (non D-Cinema content).
SUBCODE
DESCRIPTION OF USE
Replace xxx with the channel number. Valid range is 101 - 164.
Cxxx
Set to 1 to bypass and 0 to not bypass.
NONE
EXAMPLES:
(LDB+C108 1) Bypass link decryptor on channel 108.
(LCT 0) Use link decryptor on current channel (i.e. do not bypass).
(LCT+C108?) Get value for LDB on channel 108.
Link Decryptor Installed (LDI)
Access Level: Advanced
Min Power Level: Power Down
Set LD to installed or not installed.
SUBCODE
DESCRIPTION OF USE
Set to 1 to installed and 0 to not installed.
None
EXAMPLES:
(LDI 1) Set LD installed.
Lamp Intensity Calibration (LEN)
Define model and serial number for primary installed lens and auxiliary lens.
SUBCODE
DESCRIPTION OF USE
Auxiliary lens model
AMOD
Auxiliary lens serial number
ASER
Main lens model
MMOD
B-10
CP2220 User Manual
020-100420-07 Rev.1 (1-2012)

Advertisement

Table of Contents
loading

Table of Contents