Section Appendix B: Serial API
Data Format (DTF)
Select data packing format for selected input. Available data formats depends on current input port (as selected by SIN).
SUBCODE
DESCRIPTION OF USE
Replace xxx with the channel number. Valid range is 101 - 164.
Cxxx
Select data format for current channel
NONE
EXAMPLES:
(DTF?) Get current data format
(DTF?L) Show entries on the list
(DTF 1) Set current data format to 1 (292: 422 Packed 12Bit)
(DTF+C108?) Get data format on channel 108
(DTF+C108 20) Use data format 20 (DVI: Unpacked 8Bit) on channel 108
Enable Error Messages (EME)
Enable broadcasting error messages.
SUBCODE
DESCRIPTION OF USE
0 - No Fan Fail warning will be generated,
FANF
1 - Fan Fail warning will be generated.
0 - Disable broadcast,
NONE
1 - Enable broadcast of error messages to all connected serial ports and telenet sessions.
0 - No Over Temperature warning will be generated,
TEMP
1 - Over Temperature warning will be generated.
EXAMPLES:
(EME 1) Enable broadcasting error messages
(EME+FANF 0) Disable fan fail alarm warnings
(EME?) Requests current state of broadcast. Example response is (EME!001)
Focus Lens Position Adjustment (FCS)
Adjust lens to specific focus position with a specified direction. NOTE: This command can only be used to update
the current ILS file. Changing the focus for the current channel will change the focus for any channel using the
same ILS file.
Use command without subcode:
• If ILS is ON, motor will move to specified steps, and save data to the active channel.
• If ILS is OFF, motor will move to specified steps. Do not save data to the active channel.
SUBCODE
DESCRIPTION OF USE
Motor backlash in negative direction. Read-only.
BACN
Motor backlash in positive direction. Read-only.
BACP
Calibrate travel range and backlash on specified. Only valid parameter for this command is 1. SET only
CALB
command.
Replace Cxxx with the channel number. Valid range is 101-164.
Cxxx
Moving lens mount to a specified vertical position with a specified direction.
NONE
Motor moving range in negative direction. Read-only.
RNGN