pump switch).
Open hot water taps in kitchen and bathroom,
(set preselecting mixing taps or single-lever
fittings to "hot"). Leave the fittings open for
as long as it takes for the boiler to displace
the air and fill up and the water to flow without
interruption.
If just the cold water system is being
!
operated without using the water
heater, the heater tank also fills up
with water. To avoid frost damage the
boiler must be drained through the
drain valve even if it was not operated.
When connecting to a central water
!
supply (rural or city mains) a pressure
reduction valve must always be
installed to prevent above 2.8 bar
from developing in the water heater.

Draining the Water Heater

Switch off power to water pump (main or pump
switch).
Open hot water taps in kitchen and bathroom.
In order to check the water that is flowing out,
place an appropriate container (capacity 10
litres) beneath the drain valve (Frost Control)
drainage muff.
Turn the rotary switch on the drain valve by
180°C until it engages, whereby the push
button moves out and the drain valve opens.
Check whether all of the water in the
!
boiler (10 litres) has been drained into
the container via the drain valve.
There shall be no claims under
guarantee for damage caused by frost.

Methods of Operation

Heating is possible without restrictions with
gas, electrical and mixed operation, with or
without water.
Check to make sure the cowl is
!
unobstructed. Be sure to remove any
covers that may be present.
Turn on gas cylinder and open quick-acting
valve in the gas supply line.
Check whether the power supply fuse
protection on the camp site is adequate for
the 900W (3.9A) or 1800W (7.8A) that have
been selected using the power selector switch.
Summer Operation (boiler operation only)
Select gas or electrical operation using the
power selector switch. Illumination of the
yellow LED on the power selector switch
indicates that the unit is operating on 230v.
Mixed operation (gas and electrical) is not
possible in summer mode. With this setting
the unit automatically selects electrical
operation with a preselected power setting of
900W or 1800W.
Move the rotary switch on the control panel
to 40°C or 60°C. The green and yellow LEDs
light up.
When the selected water temperature is
reached (40°C or 60°C) the heater shuts off
and they yellow LED goes off.

Winter Operation

Heating with water temperature monitoring.
Select gas, electrical or mixed operation using
the power switch. Illumination of the yellow
LED on the power selector switch indicates
that the unit is operating with 230v.
Move rotary switch on control panel to
operating position.
Set the rotary switch to the desired thermostat
setting (1–5). The green LED for operation is
lit and simultaneously indicates the position
of the selected room temperature. The yellow
LED indicates the water's heat-up phase.
The
device
automatically
required power setting in accordance with
the temperature difference between the
temperature selected on the control panel
and the current room temperature. When the
room temperature selected on the control
panel is reached, the heater switches back to
the smallest setting and heats the water to
60°C. Once the water temperature is reached
the heater switches off and the yellow LED
goes out.