54
Make sure there is gas in the bottle and no
blockage in the gas line. At temperatures
below 5°C use propane rather than butane.
Press "Retry" once the checks are complete.
If there is a problem with the gas supply that
cannot be dealt with immediately, select the
electric only heating options instead.
Clear / open vents,
Retry after 10 minutes.
The heater has overheated due to the vents
being either closed or blocked, for example
with a cushion or a bag. Remove the blockage
and open any closed vents. Leave the heater
for 10 minutes to cool down, then try again.
Check voltage supply
Ensure voltage is above 12v and below 15v.
This can be done by recharging the battery.
Check outside flues for blockages
The space heater isn't getting enough air
through the flues. Check the flue ends and
clear any obstructions away from them.
Fault on space heater