Set up Antimicrobial Function

To actively kill Legionella, set up the
Antimicrobial function. At 2:00 every night,
the hot water will be heated to over 65°C
for 30 mins. This further reduces the risk of
Legionella.
1. Press Tool button to access the Settings
Menu (bottom right in Main Menu).
2. Press down arrow, until Antimicrobial
button is displayed.
3. Press Antimicrobial button to proceed.

Setup Standby Screen for Bedtime

The backlight on the Standby Screen can be
disturbing if the control panel is visible from
your bed. It can be inverted for white text on
black background.
1. Press Tool button to access the Settings
Menu (bottom right in Main Menu).
2. Press down arrow, until Backlight button is
displayed.
3. Press Backlight button, select Inverted to
proceed.

Maintenance

The
Alde
control
maintenance, other than cleaning of the
screen as needed. Use a microfibre cloth to
clean the touchscreen.
NB: Consider removing the Alde control panel
over winter, if the vehicle is to be kept in
storage and is susceptible to damp.

Troubleshooting

Any error messages will be displayed on
the Standby Screen. Error messages can be
cleared by switching off 12v supply to the
boiler for 10 secs.
The system is completely dead, the control
panel is blank
• Check the 20mm T3.15Amp glass fuse in
the boiler. This is located under the lid of
the black plastic service hatch, in a green
plastic fuse holder.
• Check the 12v supply to the boiler, it should
be above 12v.
• Check the 12v cable is plugged into the
boiler. Check the cable is plugged into the
Alde control panel.
"Panel failure 1" & and "Panel failure 2"
• Moisture is trapped in the control panel.
• Remove the Alde control panel from
the vehicle and air in a warm, dry place
overnight.
"Gas failure"
• Out of gas or gas is not igniting.
• Check the gas cylinder is full. Try a different
gas cylinder, ensuring it is propane gas.
"Overheat red fail" or "Overheat blue fail"
• Bleed the system of air.
• Check the fluid level in the expansion tank.
It should be 1cm above min mark when cool.
• Check the circulation pump is responding.
• Wait 15 mins for the fluid to cool down.
"Overheat PCB"
• Failsafe in boiler has triggered.
• Check the fluid level in the expansion tank.
It should be 1 cm above the Min mark when
cool.
• Check the boiler compartment is ventilated,
and that the vents are unobstructed. Do not
place stowage in the boiler compartment.