To replace bleach inlet:
When replacing the bleach inlet, apply
warm water to the bleach inlet and
gasket. Replace gasket fi rst.
Push the inlet up and into position from
the bottom of the top cover. Use
silicone sealant on bottom side of inlet
to prevent leaks around inlet. Lower
the top cover and replace the screws.
Replace hose to spout of bleach inlet
and replace front panel.
TUB COVER
The tub cover is secured to the outer
tub with eight (8) tabs. To the rear of
the tub cover you will see the flange,
sticking upwards. This is what trips the
unbalance lever on the lid switch. The
tub cover can be removed by pushing
downward on the tub cover and pulling
tabs out and away from outer tUb.
To Remove Tub Cover:
1. Disconnect power from unit before
servicing.
2. Secure lid to the top cover.
3. Remove two screws securing front
panel.
4. Remove two screws securing top
cover to cabinet, and tilt top cover
backwards.
5. Remove tub cover by unsnapping
the tabs, securing tub cover to outer
tub.
6. Reverse procedure for assembly.