Disassembly Procedures
!
Outer Tub and Spinner Removal
1. Disconnect power supply to unit.
2. Remove Top Cover.
3. Remove Console.
4. Remove Front Panel.
5. Remove Back Cover.
6. Remove Pump Hose.
7. Remove the Drain Hose
8. Remove Motor
9. Remove the two 13mm bolts securing the Rear Struts
to the base.
10.Rotate the struts up against the bottom of the tub to
ease removal of the tub assembly.
NOTE: The rear struts can be identified by the green
sleeve.
11. Remove two each side 13mm bolts securing Counter
36
WARNING
16026126 Rev. 0
To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.
Weights.
NOTE: Torque bolts to 11-22 ft lbs. during installtion.
12.Remove wire harness connectors for the heater,
Themistor and ground.
13.Remove two 13mm bolts securing the Front Struts to
base and rotate up against the bottom of the tub.
14.Insert a board or boards across the bottom of the
washer frame to use as a support when removing the
tub assembly.
1x12 - 32" long
©2005 Maytag Services