Bleach Injector System; Adjustment Of Pump Belt - Maytag LAT2300 Service Manual

Hide thumbs Also See for LAT2300:
Table of Contents

Advertisement

Pump Belt
Adjustment of Pump Belt:
1. Pull motor forward so drive belt is
tight.
2.
With washer in an upright position,
grasp the pump belt in the middle
and flex. With the belt flexed, it
should be tightened so that there is
approximately
1/4"
between the
inside surfaces of the pump belt
before movement of the motor is felt.
3.
If necessary, tilt washer and loosen
screws holding pump to base frame
and position pump to attain the
proper
1/4"
dimension.
BLEACH INJECTOR SYSTEM
The bleach injector system is located
on the left-hand side of the product.
Bleach is poured directly into the
bleach inlet, flowing through the bleach
. hose and into the bottom of the outer
tub.
Diluting of the bleach occurs during the
fill and agitation portion of the cycle.
During the spin a deflector inside of the
outer tub prevents the wash water from
being pumped up the bleach tube.
To remove bleach injector system:
If it is necessary to remove and replace
the bleach inlet, first remove the front
panel and pull bleach hose off of inlet
spout.
Remove the screws holding the top
cover and raise the top cover slightly.
Use a block to hold top cover 3" to 4"
above the tub cover. Use a blocking
material that will not damage the tub
cover.
With top cover in this position press
down firmly on bleach inlet until it is
removed through the bottom of the top
cover. Before replacing the inlet,
examine the gasket in the top cover. If
damaged, it should be replaced before
replacing the new bleach inlet.
16001145
SECTION 3. WASHER - SERVICE PROCEDURES
3-31
©1994 Maytag Corporation