Table 150 SNMP InterfaceTraps (continued)
OPTION
OBJECT LABEL
lldp
lldpRemTablesChange
transceiver-ddm
zyTransceiverDdmiTemperatur
eOutOfRange
zyTransceiverDdmiTxPowerOut
OfRange
zyTransceiverDdmiRxPowerOut
OfRange
zyTransceiverDdmiVoltageOut
OfRange
zyTransceiverDdmiTxBiasOutOf
Range
zyTransceiverDdmiTemperatur
eOutOfRangeRecovered
zyTransceiverDdmiTxPowerOut
OfRangeRecovered
zyTransceiverDdmiRxPowerOut
OfRangeRecovered
zyTransceiverDdmiVoltageOut
OfRangeRecovered
zyTransceiverDdmiTxBiasOutOf
RangeRecovered
GS2210 Series User's Guide
OBJECT ID
1.0.8802.1.1.2.0.0.1
1.3.6.1.4.1.890.1.15.3.84.3.1
1.3.6.1.4.1.890.1.15.3.84.3.2
1.3.6.1.4.1.890.1.15.3.84.3.3
1.3.6.1.4.1.890.1.15.3.84.3.4
1.3.6.1.4.1.890.1.15.3.84.3.5
1.3.6.1.4.1.890.1.15.3.84.3.6
1.3.6.1.4.1.890.1.15.3.84.3.7
1.3.6.1.4.1.890.1.15.3.84.3.8
1.3.6.1.4.1.890.1.15.3.84.3.9
1.3.6.1.4.1.890.1.15.3.84.3.10
Chapter 37 Access Control
DESCRIPTION
The trap is sent when entries in the
remote database have any updates.
Link Layer Discovery Protocol
(LLDP), defined as IEEE 802.1ab,
enables LAN devices that support
LLDP to exchange their configured
settings. This helps eliminate
configuration mismatch issues.
This trap is sent when the
transceiver temperature is above or
below the normal operating range.
This trap is sent when the
transmitted optical power is above
or below the normal operating
range.
This trap is sent when the received
optical power is above or below the
normal operating range.
This trap is sent when the
transceiver supply voltage is above
or below the normal operating
range.
This trap is sent when the
transmitter laser bias current is
above or below the normal
operating range.
This trap is sent when the
transceiver temperature is
recovered from the out of normal
operating range.
This trap is sent when the
transmitted optical power is
recovered from the out of normal
operating range.
This trap is sent when the received
optical power is recovered from the
out of normal operating range.
This trap is sent when the
transceiver supply voltage is
recovered from the out of normal
operating range.
This trap is sent when the
transmitter laser bias current is
recovered from the out of normal
operating range.
309