Enrollment Of The Control Panel To A Uc-216, 222, Ja-60K Etc; No Code Requested For; Partial Arming With F2 (Not Split System); Siren Alarm - jablotron JA-60 COMFORT Installation Manual

Hide thumbs Also See for JA-60 COMFORT:
Table of Contents

Advertisement

options:
2 8 1
2 8 0
Factory default setting: reset enabled
Note: if the Master or Service code is forgotten when the reset is disabled, the reset of the control panel will be possible
only by the manufacturer.

8.11. Enrollment of the control panel to a UC-216, 222, JA-60K etc.

The control panel can send wireless data to output modules UC-216, UC-222 and UC-260 (see 19.) It can also work as a
subsystem of another JA-60 or JA-65 control panel.
Enter the enrolling mode of the UC receiving device and then enter 299 and the control panel will generate the enroll-
ment signal.
If you want to enroll a subsystem to your control panel, enter the enrolling mode on the MASTER control panel (8.2.)
and then enter sequence 299 in the programming mode of the sub control panel.
8.12 No code requested for F1, F2, F3, F4, F8 & F9
If this parameter is enabled, no code is requested for functions F1, F2, F3, F4, F8 and F9. When this parameter is
disabled, these functions can be used only when followed by a code (Master or User) – see the following table:
function / setting
arming
partial arming
door opening
memory reading
appliance control
message listening
„code" = Master or User
Factory default setting: no code requested
Note: this feature is also selectable on the JA-60D wireless keypad and it is independent from the control panel setting.

8.13. Partial arming with F2 (not split system)

In partial arming, the control panel reacts only to detectors addressed to section A (see 8.22) and it ignores the triggering
of detectors in section B or C (except smoke and gas detectors). Partial arming can be disabled with this sequence.
options:
3 1 1
3 1 0
Factory default setting: partial arming enabled

8.14. Siren alarm

The built in siren is active when any alarm is triggered (except silent Panic alarm). The alarm indication can be disabled
with this parameter.
options:
3 2 1
3 2 0
Factory default setting: siren enabled
Alarm system JA-60 "COMFORT"
reset enabled
reset disabled
300
„code"
F 2 „code"
F 3 „code"
F 4 „code"
F 8 „code" 0
F 8 „code" 1
F 9 „code"
partial arming enabled
partial arming disabled
siren enabled
siren disabled
301
F 1
F 2
F 3
F 4
F 80
F 81
F 9
- 15 -
sequence: 2 9 9
sequence: 3 0 x
sequence: 3 1 x
sequence: 3 2 x
MDY51319

Hide quick links:

Advertisement

Table of Contents
loading