7.2.12. Partial (Home) arming with F2

In partial arming, the control panel reacts only to detectors in positions number 1 to 10 and it ignores the triggering of
detectors in positions numbered 11 to 16 (except smoke and gas detectors). Partial arming with F2 can be disabled with
this sequence.
options:
3 1 1
3 1 0
Factory default setting: partial arming enabled

7.2.13. Built in siren alarm

The built in siren sounds when any alarm is triggered (except silent Panic alarm). The alarm indication can be disabled
with this parameter.
options:
3 2 1
3 2 0
Factory default setting: siren enabled
Note: this setting does not efect to the function of the control panel's external siren 's otput terminals..

7.2.14. Exit delay audible indication

The exit delay is indicated with „beeping" of the control panel (for last five seconds, the beeping is faster). The audible
indication can be disabled with this setting.
options:
3 3 1
3 3 0
Factory default setting: indication enabled

7.2.15. Partial arming exit delay audible indication

Partial arming with F2 provides an exit delay for delayed reaction detectors in positions 1 to 10. The exit delay for partial
arming can be indicated with „beeping" of the control panel (for last five seconds the beeping is faster).
options:
3 4 1
3 4 0
Factory default setting: indication disabled
Note: when this indication is disabled, the confirmation of partial arming and disarming will automaticly be silent, regardless of the 36x setting.

7.2.16. Entrance delay audible indication

The entrance delay can be indicated with a rapid „beeping" of the control panel. This indication can be disabled with this
setting.
options:
3 5 1
3 5 0
Factory default setting: indication enabled
Alarm system JA-60 "COMFORT"
partial arming enabled
partial arming disabled
siren enabled
siren disabled
indication enabled
indication disabled
indication enabled
indication disabled
indication enabled
indication disabled
-
13 -
sequence: 3 1 x
sequence: 3 2 x
sequence: 3 3 x
sequence: 3 4 x
sequence: 3 5 x