Help; Resetting To The Factory Default Settings - Xineron FASTRAX III Instruction Manual

Network dome camera
Table of Contents

Advertisement

• Menu Panel:
- Menu: Enters programming menu.
- Esc: Cancels current inputs. Exits from currently running functions or menu, error status, etc.
- Home: Immediately calls Home function. Deletes selected value or function in programming mode.
- Ctrl Off: Control function.
ex) CTRL + Up, Down, Right, Left Button > Operated turbo mode.
- Preset: Pressing the Preset will bring up the preset programming menu.
- Auto Scan: Pressing the Scan will bring up the Auto Scan programming menu.
- Tour: Pressing the Tour button will bring up the tour programming menu directly.
- Pattern: Pressing the Pattern button will bring up the pattern programming menu directly.

4.7 Help

The Help information window will be provided as a popup window so that users can open and read it
without a need for log-in. It will offer a description on setting and Help page by which users can manipulate
the network camera without a reference to the manual.

4.8 Resetting to the factory default settings

To reset the network camera to the original factory settings, go to the Setup > System > Maintenance web
page or use the control button on the network camera, as described below:
• Using the Reset Button
Follow the instructions below to reset the network camera to the factory default settings using the
Reset Button.
1. Switch off the network camera by disconnecting the power adapter.
2. Open the lens cover.
3. Press and hold the Control Button (SW1) on the board with your finger while reconnecting the
power.