3.14 Dome Communication

To prevent damage, each dome camera must have a unique address (ID).
When installing multiple dome cameras using a multiplexer, it is suggested that the dome camera address
match the multiplexer port number.
The factory default setting is 1.
Example: Port 1 = Dome 1, Port 2 = Dome 2 ... Port 16 = Dome 16. If more than 16 dome cameras are
installed using two or more multiplexers, ID of the dome camera should be ID of MUX x No. of camera IN.
(e.g. multiplexer ID= n, Camera IN= m then ID of Dome =16x(n-1)+m )

3.15 Function Run

This Function Run menu allows you to execute the function when you use a keyboard or a DVR without
the function keys (Preset, Pattern, Tour and scan).
1. Select the desired Function by pushing Joystick Up or Down.
2. Select the number by twist the Joystick in PRESET,PATTERN,TOUR, and SCAN.
3. Press CTRL or IRIS Open to execute.
Note: To execute the function, you should save the function (PRESET, PATTERN, TOUR, and
SCAN) first.
- HOME
Select the HOME menu and press CTRL key. Then dome camera goes to the default position to which
the dome camera returns after an assigned period of inactivity passes.
The default position may be a Preset, Tour, Pattern or no action.
- AUTO PAN
You can execute the endless auto pan which is to turn one direction continuously by select the Auto Pan.
DOME COMMUNICATION SETUP
DOME ID
: 00XX
DOME ID
: XX01
PROTOCOL : AUTO
BAUDRATE : 9600
PARITY
: NONE
SAVE AND EXIT(ESC TO EXIT)
FUNCTION RUN SETUP
PRESET
PATTERN
TOUR
SCAN
HOME
AUTO PAN
EXIT (ESC TO EXIT)