4.3.24 Group E Screen 1

When the entered password was correct on the password input screen panel, 'Group E Screen 1'
screen panel would come out as shown in figure 31. This screen panel also comes out when
DOWN button (
) in 'Group E Screen 4' or UP (
of
fault
occurence,
operating/powered-on time at the time of inverter fault are shown in this screen panel.
(1) Fault index: shows the ordered number of faults. Maximally 64 fault data can be stored. Fault
index increases when the DOWN button (
index decreases when the UP button (
(2) Fault code: shows the reason of inverter fault (refer to [note]).
(3) Fault time: shows the time when the inverter fault has occured.
(4) Commanding frequency: shows the commanding frequency when the inverter fault has
occured.
(5) Output frequency: shows the output frequency when the inverter fault has occurred.
(6) Output voltage: shows the output voltage when the inverter fault has occurred.
(7) Output current: shows the output voltage when the inverter fault has occurred.
(8) Accumulated Operating time: shows the accumulated operating time from starting of inverter
operation to the occurrence of inverter fault.
(9) Accumulated powered-on time: shows the accumulated powered-on time from starting of
power-on to the occurrence of inverter fault.
UAL
UAL
UAL
fault
code,
commanding/output
Run
Run
Run
Run
time
time
time
time
Figure 30 Group E screen 1
) at the right side is touched. (New data)
Chapter4 4 4 4 . . . . Inverter Operation
Chapter
Chapter
Chapter
) button in 'Group E Screen 2' is touched. Time
frequency,
On
On
On
On
time
time
time
time
) at the right side is touched. (Old data) Fault