Hyundai N5000 Instruction Manual page 36

Multi-level inverter
Table of Contents

Advertisement

N5000 INSTRUCTION MAN
N5000 INSTRUCTION MAN
N5000 INSTRUCTION MANUAL
N5000 INSTRUCTION MAN
Accumulated supplying time: displays the accumulated time of powered-on and operation even
(11)
the inverter has not started.
DI1 (DIGITAL INPUT1): Green: digital input is entering, Black (light out): no digital input.
(12)
[Example]
: digital inputs are entering into #2, #6, and, #7 channels of DI1. No digital inputs are in #1,
#3, #4, #5, and, #8 channel.
DI2 (DIGITAL INPUT2): Green: digital input is entering, Black (light out): no digital input.
(13)
[Example]
: digital inputs are entering into #2, and #5channels of DI2. No digital inputs are in #1, #3,
#4, #6, #7, and #8 channel.
DO (DIGITAL OUTPUT): Green: digital out, Black (light out): no digital out.
(14)
[Example]
: digital outputs are going out through #1, #3, and #5 channels of DO. No digital inputs are
in #2, #4, #6, #7, and #8 channel.
MAS (Master) / SLV (Slave):
(15)
Unified controller (not dualized):
Green light is always on at MAS lamp.
Dualized controller:
Master controller active
Master controller inactive by controller failure
Slave controller active
[Example]
UAL
UAL
UAL
green light is on at MAS lamp.
green light is on ate SLV lamp.
33
Chapter4 4 4 4 . . . . Inverter Operation
Chapter
Inverter Operation
Chapter
Chapter
Inverter Operation
Inverter Operation
turns off MAS lamp.