(7) Voltage limit: Output frequency remains still while DC-link voltage of power cell is above the
voltage limit. When the DC-link voltage goes below the voltage limit, output frequency
resumes its accelerating/decelerating operation. [Reference7] Set the value in [%] unit out
of rated voltage of DC-LINK (100%). The rated voltage of DC-LINK of N5000 is 850[V].
(8) Current limit: Output frequency remains still while output current is above the current limit.
When the output current goes below the current limit, output frequency resumes its
accelerating/decelerating operation. [Reference7] set the value in [%] unit out of the rated
current (100%) of the motor. The rated current value of the motor can be set in the 'Group H
Screen 2' screen panel.
[Reference 7]
Voltage limits level
Current limits level
Commend frequency
Relationship between voltage/current limit and output frequency