3.1 Specification

Item
Item
Item
Item
Inverter Type
Input Voltage
Input Transformer
Input Frequency
Input Rectification
Input Current Harmonics
Input Power-Factor
Output voltage
Output voltage level
Output Frequency
Rated operation range
Main power element &
modulation method
Efficiency
Cooling
Standard
Ambient temperature
Humidity
C C C C hapter3. Specification and Operation
hapter3. Specification and Operation
hapter3. Specification and Operation
hapter3. Specification and Operation
Voltage type (Series connection with H-bridge circuit, multilevel
output)
3 kV class: 1) 3300V ±10%, 2) 3000V ±10%
6 kV class: 1) 6600V ±10%, 2) 6000V ±10%
Dry type multiphase coil transformer with built-in panel
50Hz/60Hz
3kV class: 18pulse diode rectification, 6k class: 36pulse diode
rectification
THD < 5%
0.95 (20%~100% load condition)
3phase 0~3000V, 0~3300V, 0~6000V, 0~6600V
3kV: 13 level (space voltage), 6kV: 25 level (space voltage)
~120Hz
100% load: continuous operation, 120% overload: 1min
IGBT, PWM
96% (rated operation)
Compulsive air cooling
IEC
0℃∼40℃
5%∼90% Non-condensing