Resetting An Alarm (Stopping A Warning) [Alarm Ack]; Displaying Parallel Line Cursors [Menu], [Vrm], [Ebl] - JRC JMA-5104 Instruction Manual

Marine radar equipment
Hide thumbs Also See for JMA-5104:
Table of Contents

Advertisement

Caution
● ● ● ● An alarm level 0 to 15 can be set as the volume of the alarm. As a lower value is
specified, the alarm responds to a weaker target.
Be careful that if a set alarm level is too high, the alarm may not work when it
should.

3.5.17 Resetting an alarm (stopping a warning) [ALARM ACK]

This section explains how to stop the alarm when an alarm is issued as a warning.
Stopping the alarm
Press [ALARM ACK] key.
The alarm stops.

3.5.18 Displaying parallel line cursors [MENU], [VRM], [EBL]

Parallel line cursors are displayed across the whole PPI display.
When parallel line cursors are displayed, VRM2 and EBL2 are used to set the turning angle and
the spacing of parallel line cursors.
Displaying parallel line cursors
Take the following steps to display parallel line cursors:
(a) Press the [MENU] key to display MENU .
(b) Select DISP OPTIONS and then PARALLEL LINE pressing the [JOG DIAL] or
[ACQ/ENT] key after each selection.
(c) The menu below is displayed. Turn [JOG DIAL] to select ON , and then press the [JOG
DIAL] or [ACQ/ENT] key to determine the selection.
The parallel line cursors turn in the direction in which EBL2 turns.
The spacing of parallel line cursors can be changed in the direction in which VRM2 turns.
DISP OPTIONS
EBL BEARING
TRUE
FROATING EBL
OFF
PARALLEL LINE
OFF
OFF
NM
ON
NM
WAYPOINT
OFF
POSITION
LL
LL-TD CONV>