JRC JMA-5104 Instruction Manual page 170

Marine radar equipment
Hide thumbs Also See for JMA-5104:
Table of Contents

Advertisement

NOTE:When removing or touching the PC4201.
Set the gyro power supply switch S1 to OFF
or cut-off the gyro signal input to TB10 or
J4202 in order to prevent damages to ICs
and to avoid electrical shocks.
Data Output
S5
J4201
S6
S4 S3
BSH
NORML
JP1
S2
S1
TB1
TB2
J4202
Gyro signal input
Log signal input
NOTE1: Do not forget to select the switch S1( ) to OFF before performing the connection of gyro.
If the switch S1( ) is set to ON without the correct setting of S2( ) fuses F1 F4( ) may burn out.
When setting the switch S1( ) to ON, following settings must be all completed.
NOTE2: Fuses are F1 F4( ) and are used in each lines of gyro signals and exterior power supply line.
When the fuse has burned out, replace with same type fuse after investigating the cause of burn out.
Fuse is ME51NN-0.5A.
NOTE3: Selector of applicable gyro. Setting of S2( ) and S5( ) and JP1( ) should be made correctly in accordance with the setting
table.
The revolution derection(bit8) of S5( )-4 after energized and if the revolution is reversed. If should be changed over.
NOTE4: S5( )-5 8 deawing are setting for speed log signals of the ships.
NOTE5: The electoric current for gyro signals is as follows.
Step Type
100mA(DC24V)
70mA(DC35V)
Synchro Type 50mA(AC100V)
NOTE6: S6( ) Log test switch for 18KT speed Log signal output. Usually set [NORMAL] side.
a. S5( ) Gyro/Log Type selector switch.
S5 setting to be mode according to
setting table.
1 2 3 4 5 6 7 8
ON : 1
to be
OFF : 0
specified
S5 SETTING TABLE
1
2
3
4
5
6
7
8
SYNC 0
STEP 1
360X
0
0
180X
0
1
90X
1
0
36X
1
1
Normal(NOR) 0
DIRECTION Reverse(REV) 1
PULSE
0
TYPE
SYNCHRO
1
0
800P/360X
0
0
PULSE/NM
400P/180X
0
1
200P/90X
1
0
100P/30X
1
1
SETTING GYRO SWITCH
b. S2( ) Gyro Type Selector
d. S3( ),S4( ) is used by Service person
SYNC
Synchro Type
STEP
Step Type
c. JP1( ) Gyro Type Selector
e. S1( ) Gyro power supply switch
SYNC
Synchro Type
Step Type
STEP
f. S7( ) User Type selection switch
BSH side : IMO(BSH) Type Approved RADAR
NORMAL side : Other Conventional RADAR
- S3( ) reset the CPU.
- S4( ) is setting for "0" degree of the
bearing.
After comfirming the
ON
completion of all
setting , set to ON .
OFF

Advertisement