Zone Programming Default Values

Zone Programming Notes
1.
Zone 1 is a hardwire zone; Zones 95, 96 and 99 are keypad panics.
2.
For the LYNX Touch L5200/L5200CN Zones 2 to 64 are RF zones (Zones 46 to 48 are reserved for Garage Door Zones); Zones 140-155
are RF Button Zones and 180-185 are Temperature Zones.
3.
For the LYNX Touch L7000/L7000CN Zones 2 to 70 are RF zones (Zones 45 to 48 are reserved for Garage Door Zones); Zones 140-163
are RF Button Zones and 180-187 are Temperature Zones.
4.
The default values shown below are for the LYNX Touch L5200/L5200CN.
Zone Assignment/Alarm Response Types for Configuration 1
Zone
Loop
Device Type
Number
Number
1
---
2
2
Door
3
2
Door
4
2
Window
5
1
Motion Sensor
46
1
47
1
48
1
140
3
4 Button
141
2
4 Button
142
4
4 Button
143
1
4 Button
144
3
4 Button
145
2
4 Button
146
4
4 Button
147
1
4 Button
180
---
Temperature
181
---
Temperature
182
---
Temperature
183
---
Temperature
184
---
Temperature
185
---
Temperature
95
---
96
---
Medical
99
---
Police
Zone Assignment/Alarm Response Types for Configuration 2
Zone
Loop
Device Type
Number
Number
1
---
2
2
Door
3
2
Door
4
2
Door
5
1
Motion Sensor
6
1
Smoke Detector
46
1
47
1
48
1
140
3
4 Button
141
2
4 Button
142
4
4 Button
143
1
4 Button
144
3
4 Button
145
2
4 Button
146
4
4 Button
147
1
4 Button
180
---
Temperature
181
---
Temperature
182
---
Temperature
183
---
Temperature
184
---
Temperature
185
---
Temperature
95
---
96
---
Medical
99
---
Police
Response Type
New
Not Used
Entry Exit 1
Entry Exit 1
Perimeter
Interior With Delay
New
Not Used
New
Not Used
New
Not Used
Arm Away
Disarm
Arm Stay
No Response
Arm Away
Disarm
Arm Stay
No Response
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Fire
Fire No Verification
Not Used
24-Hour Silent
Response Type
New
Not Used
Entry Exit 1
Entry Exit 1
Entry Exit 1
Interior With Delay
Fire No Verification
New
Not Used
New
Not Used
New
Not Used
Arm Away
Disarm
Arm Stay
No Response
Arm Away
Disarm
Arm Stay
No Response
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Fire
Fire No Verification
24-Hour Auxiliary
24-Hour Audible
Alarm
Chime
Supervision
Report
Yes
Disabled
End of Line
Yes
Standard
Supervised
Yes
Standard
Supervised
Yes
Standard
Supervised
Yes
Disabled
Supervised
No
Standard
Supervised
No
Standard
Supervised
No
Standard
Supervised
Yes
Disabled
Button
Yes
Disabled
Button
Yes
Disabled
Button
No
Disabled
Button
Yes
Disabled
Button
Yes
Disabled
Button
Yes
Disabled
Button
No
Disabled
Button
Yes
Disabled
High Temp
Yes
Disabled
Low Temp
Yes
Disabled
High Temp
Yes
Disabled
Low Temp
Yes
Disabled
High Temp
Yes
Disabled
Low Temp
Yes
Disabled
Panic Trigger
Yes
Disabled
Panic Trigger
Yes
Disabled
Panic Trigger
Alarm
Chime
Supervision
Report
Yes
Disabled
End of Line
Yes
Standard
Supervised
Yes
Standard
Supervised
Yes
Standard
Supervised
Yes
Disabled
Supervised
Yes
Disabled
Supervised
No
Standard
Supervised
No
Standard
Supervised
No
Standard
Supervised
Yes
Disabled
Button
Yes
Disabled
Button
Yes
Disabled
Button
No
Disabled
Button
Yes
Disabled
Button
Yes
Disabled
Button
Yes
Disabled
Button
No
Disabled
Button
Yes
Disabled
High Temp
Yes
Disabled
Low Temp
Yes
Disabled
High Temp
Yes
Disabled
Low Temp
Yes
Disabled
High Temp
Yes
Disabled
Low Temp
Yes
Disabled
Panic Trigger
Yes
Disabled
Panic Trigger
Yes
Disabled
Panic Trigger
- 76 -
Arm
Zone Descriptor
Night
n/a
n/a
n/a
Front
n/a
Back
n/a
n/a
No
n/a
n/a
Main
n/a
Main
n/a
Main
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Arm
Zone Descriptor
Night
n/a
n/a
n/a
Front
n/a
Back
n/a
Garage
No
n/a
n/a
n/a
n/a
Main
n/a
Main
n/a
Main
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lynx touch l7000 series

Table of Contents