About Zone Programming

56 Zone Programming is used to program zones, zone types, report codes, enroll 5800 RF
Wireless Transmitter serial numbers, and identify the type of loop input device(s). This mode
can also be used to enter alpha descriptors for programmed zones; however, we recommend
entering descriptors in menu mode
programming has been completed).
For a faster method of zone programming, you can use the
instead of
who have had previous experience in programming control panels of this type.
NOTE: Alpha display prompts are shown in a double-line box.

56 Zone Programming Procedure

Zone Programming involves:
1. Entering the zone number to be programmed
2. Making appropriate entries at the prompts
3. Confirming the serial number of wireless transmitter zones.
Start Zone Programming mode by pressing
following prompts are displayed:
PROMPT
SET TO CONFIRM?
0 = NO 1 = YES
Enter Zn Num.
(00 = Quit)
Zn ZT RC
In: L
10 00 10
RF: 1
www.PDF-Zoo.com
56 Zone programming. The
VALID ENTRIES
Set to Confirm
0 = no
1 = yes
Zone Number
wireless zones 01-32
10
button zones 33-40
91 = addr. device report enable
92 = duress report enable
95, 96, 99 =emergency zones
00 to quit
[∗] to continue
Summary Screen
[∗] to continue
firealarmresources.com
Zone Programming
( ✱ ✱ ✱ ✱ 56 and ✱ ✱ ✱ ✱ 58 Menu Modes)
82 (Alpha Descriptor Programming after all zone
58 Expert Programming Mode
58 Expert Programming Mode is designed for those
56 while in Data Programming mode. The
EXPLANATION
If 1 (Yes) is entered, you will be prompted to confirm each transmitter
after entering the serial and loop numbers (at the "XMIT TO
CONFIRM" prompt later in this procedure). We recommend that
you confirm the programming of every transmitter.
Enter the zone number that you wish to program. Zone 10 has been
entered as an example in the display at left.
Enter a report code for zone 91 to enable alarm reporting for
addressable devices.
Enter a report code for zone 92 to enable duress reporting.
95, 96, 99 are emergency (panic) key zones.
A summary display appears.
"IN: L" appears for wireless zones and indicates input type and loop.