Honeywell Lynx Touch L5200 Programming Manual

Honeywell Lynx Touch L5200 Programming Manual

All-in-one home and business control system and alarm control panel
Hide thumbs Also See for Lynx Touch L5200:

Advertisement

LYNX Touch
L5200/L7000 Series

Security System

Programming Guide
800-16085
12/13 Rev. A
L5200/L7000

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Lynx Touch L5200

  • Page 1: Security System

    LYNX Touch L5200/L7000 Series Security System Programming Guide 800-16085 12/13 Rev. A L5200/L7000...
  • Page 2: Table Of Contents

    Explanation of Zone Assignment Table Headings ..................... 20 5800 Series Transmitter Loop Numbers Diagram ....................23 LYNX Touch L5200 Programming Default Values ....................24 LYNX Touch L7000 Programming Default Values ....................27 LYNX Touch Series Summary of Connections Diagram ..................31 Refer to the LYNX Touch Series Installation and Setup Guide P/N 800-16082 or later for detailed information on programming the system.
  • Page 3: Entering Programming Mode

    Entering Programming Mode You may find it convenient to adjust the volume setting before entering the Programming Mode. This will allow you to clearly hear feedback announcements or system beeps. 1. Power-up the control and allow it to “boot-up”. “System Standby” is displayed on the touch screen. When the “boot-up”...
  • Page 4: Data Fields

    Screen Display Function & Programming Options DATA FIELDS Note: Preprogrammed defaults are shown on the screen display. Change Installer Code Installer Code Installer Code Enter 4 digits [The defaulted Installer Code is 4112] 5000-100-129-V0 Program System Type RF Jam RF Jam Disabled Disabled RF Jam Log...
  • Page 5: Program Date And Time

    Screen Display Function & Programming Options Events – Log Trouble Events – Log Trouble Enabled Enabled Disabled Non Security Non Security Enabled Enabled Disabled Remote Access Serial Remote Access Serial Enabled Disabled Disabled Note: If the “Remote Access Serial” option is enabled, you will be prompted to select a “Multi Mode Serial”.
  • Page 6: Program Communications

    Screen Display Function & Programming Options Start Week End Week First First Second Third Fourth Last Next to Last 3rd from Last Program Communications Communicator Program the following options: Communicator Communications Path City ID CS ID Sub ID 5000-100-132-V0 Supervision Old Alarm Time Remote Acc.
  • Page 7: Program Zones

    Screen Display Function & Programming Options IP Fault Time (min) (displayed if IP is selected as Communications Path) IP Fault Time (min) Enter 2-digits 00-99 Use DHCP Use DHCP Note: If disabled the following options will be active. NIC IP Address (Appears only if “no” was selected in the “Use DHCP Field”) NIC IP Address Enter 4 part address 255.255.255.255...
  • Page 8 Screen Display Function & Programming Options third transmission will confirm the serial number. The system beeps two times and returns to the Zone programming Screen. Enroll Manually Enter the 7-digit serial number printed on the transmitter using the displayed keypad and select “Done”.
  • Page 9: Program Keys

    Screen Display Function & Programming Options Program Keys Keys Keys Select from the following options: Edit Add New Delete If add new is selected the following options can be programmed: Key Type User Serial Number Zone Button Key 1 – Zn 140 Button Key 2 –...
  • Page 10: Program Reporter

    Screen Display Function & Programming Options Program Reporter Reporter Reporter Note: The Follow Me Phone features are not available on the LYNX Touch L7000. Program the following options: Primary CS Info Secondary CS Info Follow Me Phone 1 Follow Me Phone 2 Report Selection Options Downloader...
  • Page 11 Screen Display Function & Programming Options Secondary Central Station Information Secondary CS Info Phone Type Communicator Type Phone Type Phone Type None None Contact Id: 4 Digit Contact Id: 10 Digit Note: If SIA, Contact Id: 4 Digit or Contact Id: 10 Digit is selected, the Phone Number and Account Number options will be displayed.
  • Page 12 Screen Display Function & Programming Options Phone Type (This feature is not available on the LYNX Touch L7000) Phone Type None None Follow Me (If Follow Me is selected several new options will be displayed) Phone Number (This feature is not available on the LYNX Touch L7000) Phone Number Enter the Follow Me Phone Number None...
  • Page 13 Screen Display Function & Programming Options Disarm Exit Error AC Loss AC Loss Restore Recent Closing Event Log Full Low Battery Low Battery Restore Trouble Trouble Restore RF Low Battery RF Low Battery Restore Alarm Restore Alarm Cancel Test Test Restore Arm Away Arm Away Disabled...
  • Page 14 Screen Display Function & Programming Options Low Battery Restore Low Battery Restore Disabled Enabled Enabled RF Low Battery RF Low Battery Disabled Enabled Enabled RF Low Battery Restore RF Low Battery Restore Disabled Enabled Enabled Options Options Choose from the following options: Call Wait Cancel Number of Reports Alarm Report Delay...
  • Page 15: Program Sounder

    Screen Display Function & Programming Options (If No is selected the Ring Counter Option will be displayed.) Ring Counter (displayed if Ans. Machine Defeat is set to “No”) Ring Counter Enter ring counter (1-14) Callback Number Callback Number Enter a Callback Number Flexible Callback Flexible Callback (If Yes is selected the Number Option will be displayed.)
  • Page 16: Program System Settings

    Screen Display Function & Programming Options Program System Settings System Settings System Settings Choose from the following options: Entry Delay 1 Entry Delay 1 Exit Delay Backlight Timeout Quick Arm Quick Exit Restart Exit Time Force Bypass Exit Warning Auto Stay Arming Lack of Usage Notify Power-up in Previous Display Alarm Cancel...
  • Page 17: Program The Z-Wave Module

    Screen Display Function & Programming Options Lack of Usage Notify Lack of Usage Notify Disabled Disabled 1 Day 7 Days 27 Days 90 Days 180 Days 365 Days Power-Up in Previous State Power-Up in Previous Always Enabled (not selectable) Display Alarm Cancel Display Alarm Cancel Display Exit Time Display Exit Time...
  • Page 18: Communication Diagnostics

    Communications Diagnostics Note: For additional information regarding these fields, refer to the LYNX Touch Installation and Setup Guide P/N 800-16082 or higher. Communication Diagnostics Comm. Diagnostics Choose from the following options (depending upon the Communication Module that is installed: Communication Ethernet Status Information...
  • Page 19 Communications Diagnostics Test Communication - Performs network diagnostics and sends test alarms to the network. The following tests are available depending on the type of communications module installed. Message Function Send Cellular Message: Available if Cellular communication path is enabled Test Ethernet: Available if IP communication path is enabled Send Ethernet Message:...
  • Page 20: Zone Programming Worksheet

    Zone Programming Worksheet Fill in the required data on this worksheet, then follow the programming procedure. (The defaults shown are for Configuration 1) See Explanation of Zone Assignment Table Headings Note: Zones 65-70, 156-163, and 186-187 are only available on the LYNX Touch L7000 control. In addition, Zone 45 can only be programmed as a Garage Zone on the on the LYNX Touch L7000 control.
  • Page 21 Zone Programming Worksheet Zone Loop Device Response Transmitter Zone Type Type Report Chime Supervision Night Serial Number Descriptor Not Used Standard Supervised Main Not Used Standard Supervised Main Not Used Standard Supervised Main Not Used Standard Supervised Main 4 Button Arm Away Disabled Button...
  • Page 22 Zone Programming Worksheet Zone Loop Device Response Transmitter Zone Type Type Report Chime Supervision Night Serial Number Descriptor Temperature Not used Disabled High Temp Temperature Not used Disabled Low Temp Temperature Not used Disabled High Temp Temperature Not used Disabled Low Temp Temperature Not used...
  • Page 23: 5800 Series Transmitter Loop Numbers Diagram

    5800 Series Transmitter Loop Numbers LOOP 1 LOOP 1 (LOW (LOW SENSITIVITY SENSITIVITY LOOP LOOP 2 LOOP 2 (HIGH (HIGH LOOP 1 SENSITIVITY) SENSITIVITY) LOOP LOOP 3 (TEMP) LOOP 3 (TEMP) LOOP 4 (TAMPER) LOOP 4 (TAMPER) 5 8 0 0 C O 5 8 0 0 M i c r a 5 8 0 0 P I R - R E S 5 8 0 0 P I R / 5 8 0 0 P I R - C O M...
  • Page 24: Lynx Touch L5200 Programming Default Values

    L5200 Programming Default Values Program Function Configuration 1 Configuration 2 Configuration 3 Configuration 4 Installer Code 4112 4112 4112 4112 System Type RF Jam Disabled Disabled Disabled Disabled Speaker Phone Disabled Disabled Disabled Disabled Two Way Voice Disabled Disabled Disabled Disabled RF House Code Phone Notification...
  • Page 25 Program Function Configuration 1 Configuration 2 Configuration 3 Configuration 4 Account Number FFFF FFFF FFFF FFFF Dynamic Priority None None None None Dynamic Delay None None None None Report All Press to Report All Press to Report All Press to Report All Press to Report All Report Alarms Enabled...
  • Page 26 Program Function Configuration 1 Configuration 2 Configuration 3 Configuration 4 AC Loss Enabled Enabled Enabled Enabled AC Loss Restore Enabled Enabled Enabled Enabled Low Battery Enabled Enabled Enabled Enabled Low Battery Restore Enabled Enabled Enabled Enabled RF Low Battery Enabled Enabled Enabled Enabled...
  • Page 27: Lynx Touch L7000 Programming Default Values

    L7000 Programming Default Values Program Function Configuration 1 Configuration 2 Configuration 3 Configuration 4 Installer Code 4112 4112 4112 4112 System Type RF Jam Disabled Disabled Disabled Disabled Speaker Phone Disabled Disabled Disabled Disabled Two Way Voice Disabled Disabled Disabled Disabled RF House Code Phone Notification...
  • Page 28 Program Function Configuration 1 Configuration 2 Configuration 3 Configuration 4 Phone Number Blank Blank Blank Blank Account Number FFFF FFFF FFFF FFFF Dynamic Priority None None None None Dynamic Delay None None None None Report All Press to Report All Press to Report All Press to Report All Press to Report All...
  • Page 29 Program Function Configuration 1 Configuration 2 Configuration 3 Configuration 4 Bypass Restore Enabled Enabled Enabled Enabled AC Loss Enabled Enabled Enabled Enabled AC Loss Restore Enabled Enabled Enabled Enabled Low Battery Enabled Enabled Enabled Enabled Low Battery Restore Enabled Enabled Enabled Enabled RF Low Battery...
  • Page 30 - Notes - - 30 -...
  • Page 31: Lynx Touch Series Summary Of Connections Diagram

    - 31 -...
  • Page 32 2013 Ê800-16085KŠ 800-16085 12/13 Rev. A...