  • Page 1: Security System

    LYNX Touch L7000 Series Security System User Guide 800-16084 12/13 Rev. A LYNX Touch L7000 Series...
  • Page 2 Your Honeywell security system is designed for use with devices manufactured or approved by Honeywell for use with your security system. Your Honeywell security system is not designed for use with any device that may be attached to your security system's control or other communicating bus if Honeywell has not approved such device for use with your security system.
  • Page 3: Table Of Contents

    INDEX ..................................77 TWO YEAR LIMITED WARRANTY ........................79 Congratulations on your ownership of a Honeywell Security System. You have made a wise decision in choosing it, for it represents the latest in security protection technology today. Honeywell is the world's largest manufacturer of security systems and millions of premises are protected by Honeywell products.
  • Page 4 – 4 –...
  • Page 5: System Overview

    SYSTEM OVERVIEW SYSTEM OVERVIEW SYSTEM OVERVIEW SYSTEM OVERVIEW Features General Information This system offers you three forms of protection: burglary, fire, and emergency, depending on the configuration of your system. The system consists of a touch screen control for system operation, various wireless sensors that provide perimeter and interior burglary protection, and optional smoke or combustion detectors to provide early fire warning.
  • Page 6: Fire Protection

    Alarms When an alarm occurs, the LYNX Touch internal sounder will sound for about 15-seconds, and the touch screen displays the zone(s) causing the alarm. After 15-seconds, the internal sounder stops temporarily and voice announcements of the zones in alarm begins. When these zones have been announced, the internal sounder sounds again and the cycle repeats itself, until the system is disarmed or until alarm bell timeout occurs.
  • Page 7: General Operation

    LYNX Touch False Alarm Prevention Features Many false alarms are caused by simple accidents, like forgetting to close a door when you leave. The LYNX Touch may include several features that help prevent false alarms and some of these are optional or programmable. Although turning off some of these features may provide additional security, it may also increase the chance of false alarms.
  • Page 8: Quick View Of System Functions

    Disarm system and silence alarms ..........: Disarm Note: During Entry Delay or when an Alarm Condition exists, the LYNX Touch can be disarmed by entering the User Code. Entering the OFF key is not required Arm Instant ................... : Set “Delay”...
  • Page 9: Quick View Of System Functions

    SYSTEM OVERVIEW SYSTEM OVERVIEW SYSTEM OVERVIEW SYSTEM OVERVIEW Quick View of System Functions Function Press these Keys or Icons OTHER FUNCTIONS (accessible from the Master User Screen) + Master Code Tools Set the time and date ..............: Date Time Add, delete or change a User Code* ...........
  • Page 10: About The Touch Screen Control

    General **IMPORTANT** If the LYNX Touch is beeping rapidly upon entering the premises, an alarm has occurred during your absence and an intruder may still be on the premises. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location.
  • Page 11: About The Display And Indicators

    SYSTEM OVERVIEW STEM OVERVIEW STEM OVERVIEW STEM OVERVIEW About the Display and Indicators Display Definitions DEFINITION ICON TEXT Displayed along with the the text “Ready To Arm” when system is Disarmed and Ready to Arm ready to arm. “Armed Away” is displayed along the top of the screen. An armed away icon Armed Away along with “Armed Away”...
  • Page 12 SYSTEM OVERVIEW SYSTEM OVERVIEW SYSTEM OVERVIEW SYSTEM OVERVIEW About the Display and Indicators DEFINITION ICON TEXT “Not Ready To Arm – System Trouble” is displayed in a yellow status bar along Low Battery the top of the screen. A low battery icon along with “Low Battery” is displayed when the system’s backup battery power is low.
  • Page 13: Navigating Menus

    Navigating Menus LCD Display LYNX Touch’s Liquid Crystal Display (LCD) touch screen displays variable icons and text on “screens”. The screen displays status icons and associated text, the current time, system status information and menu choices. The system status is displayed in a colored status bar along the top of the screen. The status bar color is variable and will change between Red, Yellow and Green as the system status changes.
  • Page 14: Function Keys

    PANIC HOME FUNCTION FUNCTION 7000-100-012-V1 LYNX Touch Security Screen (Page 1) Menu Screens System Status is displayed at the top of each screen. The time and date are displayed at the bottom of the Security Screen. Menus Security Screen Menu The two-page Security Screen provides access to an Unrestricted Menu that displays the system status and selection icons or “buttons”.
  • Page 15 SYSTEM OVERVIEW SYSTEM OVERVIEW SYSTEM OVERVIEW SYSTEM OVERVIEW Navigating Menus Master Menu The User Menu provides access to User configurable features. The appearance of the icons varies dependent upon the options that have been programmed. Entering the Master User Code is required to access the Master menu.
  • Page 16: Securing The Premises

    SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES System Status General Information Before arming your system, all protected doors, windows, and other protection zones must be closed or bypassed (refer to the Bypassing Zones section). Home Key: The Home Key (Ready indicator) on the control will be lit Green when the system is ready to be armed.
  • Page 17: Arming The System

    SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES Arming the System Arming in Stay Mode Use this mode when you are staying home, but expect someone to use the entrance door later. Close all protected perimeter windows and doors before arming. The green Ready indicator on the control should be lit if the system is ready to be armed.
  • Page 18: Auto Stay Arming Feature

    Auto Stay Arming Feature If this feature is enabled by installer, the LYNX Touch, when armed AWAY from the control’s keypad or a Wireless Keypad, automatically switches to the STAY mode if the Exit Time expires and no exit has been made. Exit must be made through an Entry/Exit Zone (door).
  • Page 19 SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES Arming the System Ready To Arm 2. Select the ”Arm Night”, then enter a valid User Code. Arm the system in Stay mode If Quick Arm has been enabled, select the “Quick Arm” icon. Enter Code: Note: If a valid user code is not entered or the Confirm icon has not been selected within 10 seconds, the system returns to...
  • Page 20 SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES Arming the System Arming In Away Mode Use this mode when no one will be staying on the premises. Close all protected perimeter windows and doors before arming. The green Ready indicator on the control should be lit if the system is ready to be armed. When armed in AWAY mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises, when infrared detection devices are used.
  • Page 21 “home” screen and it will not be armed. Silent Exit Feature If Silent Exit feature is enabled, when the LYNX Touch is armed AWAY, the Exit beeps will be silenced. In addition, the panel will double the exit delay time before arming AWAY.
  • Page 22 SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES Arming the System Armed Away At the end of the exit delay the system will announce “Armed Away” and displays the “Armed Away” screen. Zones System Disarm Message More 10:18 AM June 8, 2010 7000-100-024-V0...
  • Page 23 SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES Arming the System Arming the System with no delay (Instant) Use “Instant” with Stay mode when you are staying home and do not expect anyone to use the entrance door. Use “Instant”...
  • Page 24: Entry/Exit Delays

    SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES Entry/Exit Delays Entry/Exit Delays Entry/Exit Delays Entry/Exit Delays Exit Delay Exit delay begins immediately after arming the system, and gives you time to leave through the designated exit door without setting off an alarm.
  • Page 25 None, 15, 30, 45, 60, 90 seconds, 2, 3, 4 minutes Entry Delay 2: None, 15, 30, 45, 60, 90 seconds, 2, 3, 4 minutes LYNX Touch (L7000CN) Canada Exit/Entry Delay Times Exit Delay: None, 15, 30, 45, 60, 90 seconds, 2 minutes...
  • Page 26: Disarming The System

    **IMPORTANT** If the LYNX Touch is beeping rapidly upon entering the premises, an alarm has occurred during your absence and an intruder may still be on the premises. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location.
  • Page 27 SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES Disarming the System When an Alarm Occurs When an alarm has occurred, the touch screen displays the zone number(s) that caused the alarm and the type of alarm (e.g., “Fire Alarm”). These messages remain displayed until cleared by a user. To clear the display, note the zone number that is displayed and enter an Off sequence.
  • Page 28: Bypassing Protection Zones

    SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES Bypassing Protection Zones Bypassing Individual Zones The Bypass feature can be used when you want to intentionally arm your system with one or more zones unprotected. Bypassed zones are unprotected and will not cause an alarm when violated while your system is armed.
  • Page 29 SECURING SECURING THE PREMISES THE PREMISES SECURING SECURING THE PREMISES THE PREMISES Bypassing Protection Zones Displaying/Clearing Bypassed Zones Ready To Arm - Bypass 1. With the system in the disarmed state, select the “Zones” icon. The system displays the Zone screen and the status for each zone will be indicated.
  • Page 30: Panic Keys

    SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES Panic Keys Panic Keys Your system may have been programmed to use special icons to manually activate panic functions. The functions that might be programmed are listed below. See your installer for the function(s) that may have been programmed for your system.
  • Page 31: Chime Mode

    SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES Chime Mode Chime Mode Your system can be set to provide you with an audible alert of the opening of a door, while it is disarmed, by using Chime mode. When activated, three beeps or a programmed chime will sound at the control whenever a protected perimeter door is opened and the zone voice descriptor will be announced, if programmed.
  • Page 32: Voice Mode

    SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES SECURING THE PREMISES Voice Mode Voice Mode Your system can be set to provide you with a voice alert of system functions by activating the Voice mode. When activated, the system will announce the system status when armed/disarmed. Turning Voice Mode On or Off Ready To Arm 1.
  • Page 33: User Functions

    USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS User Access General Information For additional security you (the Master User Code) can assign secondary user codes to individual users enabling them to perform specific system functions. These secondary users are identified by "User Numbers" when their codes are assigned.
  • Page 34 USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS User Access Ready To Arm 4. Select the “Add New” key. The system displays the User screen. Master **** Guest **** Note: **** Following a User name indicates that a valid 4-digit User Code has been assigned to the User.
  • Page 35 USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS User Access Editing/Deleting a User Ready To Arm 1. With the system in the disarmed state, select the “Tools” icon from the second page of the Security Screen. The system displays the Keypad screen. Tools Arm Away Arm Stay...
  • Page 36 USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS User Access Ready To Arm 7. If desired, enter a new 4-digit code for the selected User followed by “Done”. The system returns to the Users screen. User Code 8. Select “Yes” or “No” when the confirmation screen is displayed then proceed to step 9.
  • Page 37: View Events

    USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS View Events This feature allows you to view System Events such as Arming/Disarming, Zone Activity, Troubles and Alarms. Viewing System Events Ready To Arm 1. With the system in the disarmed state, select the “Tools” icon from the second page of the Security Screen.
  • Page 38: Message Recording And Playback

    USER FUNCTIONS USER FUNCTIONS Message Recording and Playback The LYNX Touch Message Center allows you to record, play and delete messages. The maximum message duration is 184 seconds. NOTES: (1) If the system loses electrical power, all messages will be erased.
  • Page 39 USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS Message Recording and Playback Playing Message(s) Ready To Arm At the Message screen, select the message you wish to play. Message 1 2:48 PM September 1, 2010 Select “Play”, the system plays your message. When you are finished listening to the message, you may Message 2 5:09 PM...
  • Page 40: System Settings

    USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS System Settings The volume level of message playback, system announcements, and status beeps can be changed if desired. Additionally, you can adjust the display’s brightness and turn on or off the Chime. Change System Settings Ready To Arm 1.
  • Page 41: Clock/Calendar

    USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS Clock/Calendar Note: If your system is equipped with a 4GLT/4GLTC or ILP5 Communication Module, the time and date will be programmed and updated automatically via Central Station. You may still program the correct Time Zone as shown below. Check with your installer to see if your system is equipped with a Communications Module.
  • Page 42 USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS Clock/Calendar Ready to Arm ... 8. If the displayed time is not correct, select “Clear” then enter the correct time (4 digits) on the keypad and select AM or PM. 9. When you have finished select the “ ” icon. The system advances to the next screen OR proceed to step 17.
  • Page 43 USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS Clock/Calendar If your system is equipped with a GSMVLP5-4G/GSMVLP5CN4G, 4GL/4GLC or ILP5 Communication Module, but is not subscribed to TotalConnect Services it can be programmed to receive single day weather information. Check with your installer to see if this option is available. Enable Single Day Weather Reporting Ready To Arm 1.
  • Page 44: Automation

    USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS Automation General Information Automation is used to program triggers, send Follow-Me or E-mail messages of system events or program home automation features (Z-Wave) including Rules and Scenes (if Z-Wave communications have been enabled). Up to 40 rules can be programmed.
  • Page 45 USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS Automation 4. Select “Name”. The system displays a keypad. Ready To Arm 5. Enter a name (up to 13 digits long) for the scheduled function Name Frequency on the displayed keypad then select “Done”. None 6.
  • Page 46 USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS Automation Editing a Scheduled Function Ready To Arm 1. At the Schedules screen, select the Schedule you wish to edit. Schedule 1 Auto Arm Note: Rules 21-40 are only accessible through TotalConnect Service. Auto Stay Daily 2.
  • Page 47 USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS Automation Rules Up to 40 rules can be programmed. Rules 1 through 20 are used for Triggers, Z-Wave Scenes and Follow-Me Messages. Rules 21 through 40 are used for Z-Wave Scenes and for E-mail notification and are only accessible through TotalConnect Service.
  • Page 48 USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS Automation Ready To Arm 4. Select the “Name” key and then enter up to 13 characters of text on the displayed keyboard to assign a name to the Rule. 123!@# Note: Select the “ABC…” key to switch the keyboard between upper/lower case or the “123!@#”...
  • Page 49 USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS Automation Ready To Arm 9. Select “Stop Zone Type” The system displays the same Name options as the previous step. Note: If a Rule is being used to trigger a Z-Wave door lock, when Type Action the system is Armed Stay or Armed Away, it is...
  • Page 50 USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS Automation Editing or Deleting Rules Ready To Arm 1. At the Rules Programming Screen, select the Rule that you wish to edit or delete. Device 1 Device 2 System Armed Note: Rules 21-40 are only accessible through TotalConnect Follow Me Service.
  • Page 51: Reminders

    USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS Reminders The Reminder Feature can be used to program/record reminders that can be displayed on the touch screen, announced by the control. Programming a Reminder Ready To Arm 1. With the system in the disarmed state, select the “Tools” icon from the second page of the Security Screen.
  • Page 52 USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS Reminders Ready To Arm 5. Select “Name”. Enter a name for the scheduled function on the displayed keypad then select “Done”. Name Frequency None 6. Select “Frequency” then select one of the following displayed options: None Once...
  • Page 53 USER FUNC USER FUNCTIONS TIONS USER FUNC USER FUNC TIONS TIONS Reminders Editing a Reminder Ready To Arm 1. At the Reminders screen, select the reminder you wish to edit. Walk Dog - Daily 2. Select the “Edit” button. The Reminder programming screen will appear.
  • Page 54: Wifi Configuration

    USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS WiFi Configuration View/Join Available WiFi Networks Ready To Arm 1. At the Master User screen select the WiFi Config icon. The system displays the WiFi options screen. Users Test Keypad Events Date Time Reminders Slide Show WiFi Config...
  • Page 55 USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS WiFi Configuration Manually Configure Access Point Ready To Arm 1. At the Master User screen select the WiFi Config icon. The system displays the WiFi options screen. Users Events Test Keypad Date Time Reminders Slide Show WiFi Config...
  • Page 56 WiFi operation to occur. The LYNX Touch will support up to four Mobile Devices (or tablets) that can be used as Auxiliary Keypads. A WiFi communication device and router are required. The “Keypad” button is used to enroll/sync the mobile device with the control.
  • Page 57: Video Camera Control Feature

    Video Camera Control Feature The LYNX Touch L7000 supports up to 20 video cameras and provides the capability to view live video from a maximum of four cameras. The installation of a WiFi Communications module and a WiFi internet connection are required.
  • Page 58 USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS Video Camera Control Feature Video Camera Reset In the event that video streaming is lost, freezes or becomes the control can automatically or manually pixelated reset the video depending on the option that is selected. The system is defaulted to automatically recover within approximately 1 minute after communication has been restored.
  • Page 59 Tap two times on the video display from the camera you wish to control. The LYNX Touch displays a full screen view of the video and the camera controls that are avaiable for the selected camera. Tap the video display two times again to return to multiple camera viewing.
  • Page 60: Two Way Voice Feature (Alarm Audio Verification)

    WiFi bandwidth less than 90kbps may result in degraded performance. • Fire and CO alarms will prevent the LYNX Touch from starting an Two-Way Voice session. A new Fire or CO alarm will end a Two-Way Voice session that is in progress.
  • Page 61: Remote Services

    USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS USER FUNCTIONS Remote Services Your security system may be capable of providing a series of web-based services that allow you to communicate with your security system remotely in a number of ways. These features are enabled through Total Connect Service and provide the ability to: Access to your security system from a computer via website (Remote Access Feature) •...
  • Page 62: Slide Show

    Slide Show The LYNX Touch features a Slide Show/Screen Saver feature. The feature allows images to be displayed on the touch screen when it is not in use. Connection to Total Connect Service is required in order for your installer to upload images to your panel.
  • Page 63: Summary Of Audible & Visual Notifications

    SUMMARY OF AUDIBLE SUMMARY OF AUDIBLE & VISUAL SUMMARY OF AUDIBLE SUMMARY OF AUDIBLE & VISUAL & VISUAL NOTIFICATION & VISUAL NOTIFICATION NOTIFICATION NOTIFICATIONS S S S Audible Soundings SOUND CAUSE ANNOUNCEMENT* INTERRUPTED FIRE ALARM (3 beeps) fire alarm + zone voice descriptor CARBON MONOXIDE ALARM (4 beeps) Carbon monoxide alarm + zone voice descriptor (Voice descriptor is interlaced with the sounder and sounds every 45...
  • Page 64: System Displays

    SUMMARY OF AUDIBLE & VISUAL NOTIFICATIONS SUMMARY OF AUDIBLE & VISUAL NOTIFICATIONS SUMMARY OF AUDIBLE & VISUAL NOTIFICATIONS SUMMARY OF AUDIBLE & VISUAL NOTIFICATIONS System Displays The following icons will be displayed on the Security Screen along with specific zone status information (if applicable) to indicate system status.
  • Page 65: System Functions

    SYSTEM FUNCTIONS SYSTEM FUNCTIONS SYSTEM FUNCTIONS SYSTEM FUNCTIONS Testing the System (to be conducted weekly) Test Modes The Test icon provides access to the Walk Test and Reboot functions. The Walk Test mode allows each protection point to be checked for proper operation. When the Walk Test mode is active, the control sounds a single beep every 30 seconds as a reminder that the system is in the Test mode.
  • Page 66: Walk Test

    NOTE: If the Walk Test mode is inadvertently left active, it automatically turns off after 4 hours. The Dialer Test mode will remain active until exited via an Off sequence. LYNX Touch Exit/Entry Delay Times The LYNX Touch will send an event code to the Central Station after entering and after exiting from Test mode. – 66 –...
  • Page 67: Maintaining Your System

    SYSTEM FUNCTIONS SYSTEM FUNCTIONS SYSTEM FUNCTIONS SYSTEM FUNCTIONS Maintaining your system The components of your security system are designed to be as maintenance-free as possible. To make sure that your system is in working condition, do the following: 1. Test your system weekly (see the TESTING THE SYSTEM section). 2.
  • Page 68 Changing the LYNX Touch Series System Battery In the event of an AC power loss, the LYNX Touch Series is powered by a rechargeable, nickel-metal hydride battery pack. The battery pack should be replaced when a “Battery Low” message with no zone number is displayed.
  • Page 69: Fire/Co Alarm System

    In Case of Fire 1. Should you become aware of a fire emergency before your detectors sense the problem, go to the LYNX Touch and press and hold the panic button and then select the Fire icon. The alarm will sound and an alarm will be transmitted to the central station.
  • Page 70: National Fire Protection Association's Smoke Detector Recommendations

    FIRE/CO ALARM SYSTEM National Fire Protection Association Smoke Detector Recommendations LYNX Touch is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-SHA) is installed. With regard to the number and placement of smoke and heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's (NFPA) Standard #72 noted below.
  • Page 71: Emergency Evacuation

    FIRE/CO ALARM SYSTEM Emergency Evacuation LYNX Touch is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-SHA) is installed. Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the National Fire Protection Association: 1.
  • Page 72: Regulatory Agency Statements

    REGULATORY AGENCY STATEMENTS REGULATORY AGENCY STATEMENTS REGULATORY AGENCY STATEMENTS REGULATORY AGENCY STATEMENTS Federal Communications Commission (FCC) Part 15 The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment.
  • Page 73: Limitations Of This Alarm System

    WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons.
  • Page 74: Servicing Information

    SERVICING INFORMATION Your local Honeywell dealer is the person best qualified to service your alarm system. Arranging some kind of regular service program with him is advisable. Your local Honeywell dealer is: Name: Address: Phone: – 74 –...
  • Page 75: Owner's Insurance Premium Credit Request

    OWNER'S INSURANCE PREMIUM CREDIT REQUEST This form should be completed and forwarded to your homeowner's insurance carrier for possible premium credit. A. GENERAL INFORMATION: Insured's Name and Address: Insurance Company: Policy No.: LYNX Touch Series __________________________________________________ Other Type of Alarm: Burglary Fire Both...
  • Page 76 OWNER'S INSURANCE PREMIUM CREDIT REQUEST (cont.) E. SMOKE DETECTOR LOCATIONS Furnace Room Kitchen Bedrooms Attic Basement Living Room Dining Room Hall F. BURGLARY DETECTING DEVICE LOCATIONS: Front Door Basement Door Rear Door All Exterior Doors 1st Floor Windows All Windows Interior Locations All Accessible Openings, Including Skylights, Air Conditioners and Vents G.
  • Page 77: Index

    – INDEX – 5-Day Forecast ............13 Exit/entry delays ............7 Alarm cancelled ............ 7, 24 False alarm prevention features ......7 Alarm exit error ............24 False alarms ............7, 24 Alarm reporting delay ..........7 Features ..............5 Alarms ................
  • Page 78 Quick arm ........8, 17, 18, 19, 20, 21 Quick exit ..............23 Tablets ..............56 Talk mode ..............60 Test mode ............65, 66 Ready indicator ........ 16, 17, 18, 20, 26 Time and date ............ 14, 41 Real-time clock ............5 Touchscreen control ..........
  • Page 79: Two Year Limited Warranty

    TWO YEAR LIMITED WARRANTY Honeywell International Inc., acting through its Security & Communications business (“Seller”), 2 Corporate Center Drive, Melville, New York 11747 warrants its products to be free from defects in materials and workmanship under normal use and service, normal wear and tear excepted, for 24 months from the manufacture date code; provided, however, that in the event the Buyer presents a proper invoice relating to the purchased product and such invoice bears a date later than the manufacture date, then Seller may at its discretion, reflect the warranty period as commencing at invoice date.
  • Page 80 2013 Ê800-16084BŠ 800-16084 12/13 Rev. A...

This manual is also suitable for:

Lynx touch l7000 seriesL7000 series

Table of Contents