System Type (Continued)
Screen
Phone Notification
Disabled
Phone Detect Time
2 Minutes
Events - Log All
Log All Set
Events – Log Alarm
Enabled
Non Security
Enabled
Remote Access Serial
Disabled
Multi Mode Serial
Disabled
Note: The Phone Notification field is not available on the LYNX Touch L7000/L7000CN.
8. Select "Phone Notification" (phone line cut). The System scrolls between the following
options:
Disabled
Keypad
Trouble
If "Keypad" or "Trouble is selected proceed to Step 8.
Note: The Phone Detect Time field is not available on the LYNX Touch L7000/L7000CN.
9. If Keypad or Trouble was selected in Step 7, the "Phone Detect Time" option is displayed.
Select "Phone Detect Time". The system scrolls between the following options:
1 Minute
2 Minutes
3 Minutes
4 Minutes
Use the down  arrow to scroll to the next page of options.
10. Select "Events - Log All". The system displays "Press To Log All". Selecting this option
programs the system to log all events and "Log All Set" is displayed. Additionally all of the
options listed below are enabled.
Events – Log Alarm
Events – Log Bypass
Events – Log Open/Close
Events – Log Trouble
Non-Security
OR
Proceed to step 11 and select the options individually.
11. Select "Events – Log Alarm". The System toggles between "Enabled" and "Disabled.
12. Select "Events – Log Bypass". The System toggles between "Enabled" and "Disabled".
13. Select "Events – Log Open/Close". The System toggles between "Enabled" and
"Disabled".
14. Select "Events – Log Trouble". The System toggles between "Enabled" and "Disabled".
15. Select "Non Security". The System toggles between "Enabled" and "Disabled".
16. Select "Remote Access Serial". The System toggles between "Enabled" and "Disabled".
If the Remote Access Serial" option is enabled, the "Multi Mode Serial" option is
displayed.
Note: The Multi Mode Serial field is "Disabled" unless the Remote Access Serial field has
been set to "Enabled".
17. Select "Multi Mode Serial". The System toggles between "Enhanced Reports" and
"Disabled".
18. Select "Save" when complete.
LYNX Touch Installation and Setup Guide
Programming the Control
ACTION
- 29 -