Zone Response Type Matrix - Honeywell L5200 Series Installation And Setup Manual

Hide thumbs Also See for L5200 Series:
Table of Contents

Advertisement

Zone Assignment/Alarm Response Types for Values 3 and 4
Zone
Loop
Device Type
Number
Number
1
---
New
2
2
Door
3
2
Door
4
2
Window
5
2
Window
6
2
Window
7
2
Window
8
1
Motion Sensor
9
1
Smoke Detector
46
1
New
47
1
New
48
1
New
140
3
4 Button
141
2
4 Button
142
4
4 Button
143
1
4 Button
144
3
4 Button
145
2
4 Button
146
4
4 Button
147
1
4 Button
180
---
Temperature
181
---
Temperature
182
---
Temperature
183
---
Temperature
184
---
Temperature
185
---
Temperature
95
---
Fire
96
---
Medical
99
---
Police
Device Type
Door
Window
Motion Sensor
Glass Break
Smoke Detector
Heat Sensor
Carbon Monoxide Detector
Temperature
Flood
Environmental
Medical
Fire
Police
Garage Door
Other
Response Type
Not Used
Entry Exit 1
Entry Exit 1
Perimeter
Perimeter
Perimeter
Perimeter
Interior With Delay
Fire No Verification
Not Used
Not Used
Not Used
Arm Away
Disarm
No Response
No Response
Arm Away
Disarm
No Response
No Response
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Fire No Verification
Not Used
24-Hour Silent
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
- 77 -
LYNX Touch Installation and Setup Guide
Zone Programming Default Values
Alarm
Chime
Supervision
Report
Yes
Disabled
End of Line
Yes
Standard
Supervised
Yes
Standard
Supervised
Yes
Disabled
Supervised
Yes
Disabled
Supervised
Yes
Disabled
Supervised
Yes
Disabled
Supervised
Yes
Disabled
Supervised
Yes
Disabled
Supervised
No
Standard
Supervised
No
Standard
Supervised
No
Standard
Supervised
Yes
Disabled
Button
Yes
Disabled
Button
Yes
Disabled
Button
No
Disabled
Button
Yes
Disabled
Button
Yes
Disabled
Button
Yes
Disabled
Button
No
Disabled
Button
Yes
Disabled
High Temp
Yes
Disabled
Low Temp
Yes
Disabled
High Temp
Yes
Disabled
Low Temp
Yes
Disabled
High Temp
Yes
Disabled
Low Temp
Yes
Disabled
Panic Trigger
Yes
Disabled
Panic Trigger
Yes
Disabled
Panic Trigger

Zone Response Type Matrix

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Arm
Zone Descriptor
Night
n/a
n/a
n/a
Front
n/a
Back
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
No
n/a
n/a
n/a
n/a
Main
n/a
Main
n/a
Main
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x