Program System Settings
Note: If applicable, preprogrammed defaults for the L5200/L7000 Control are shown on the screen unless otherwise noted.
SCREEN
System Settings
Entry Delay 1
30 Seconds
Entry Delay 2
30 Seconds
Exit Delay
60 Seconds
Select "System Settings"
The System displays the following options:
Entry Delay 1
Exit Delay
Quick Arm
Force Bypass
Exit Warning
Use the down  arrow to scroll to the next page of options. Use the  arrow to return to
the previous page:
Lack of Usage Notify
Display Alarm Cancel
Cross Zone Delay
Cross Zone 1
Select "Entry Delay 1". The System scrolls between the following options:
LYNX Touch Canada
LYNX Touch
(L5200CN/L7000CN)
(L5200/L7000)
None
None
15 Seconds
15 Seconds
30 Seconds
30 Seconds
45 Seconds
45 Seconds
60 Seconds
60 Seconds
90 Seconds
90 Seconds
2 Minutes
2 Minutes
3 Minutes
4 Minutes
UL installations: The Entry Delay must be set for a maximum of 45 seconds.
SIA: The Entry delay must be set to a minimum of 30 seconds. The sum of entry delay 1 and
the Alarm Report Delay (burglary abort window) should not exceed 1 minute. "None" is
only allowed for use in Commercial High-Security applications.
Select "Entry Delay 2". The System scrolls between the following options:
LYNX Touch
LYNX Touch Canada
(L5200/L7000)
(L5200CN/L7000CN)
None
None
15 Seconds
15 Seconds
30 Seconds
30 Seconds
45 Seconds
45 Seconds
60 Seconds
60 Seconds
90 Seconds
90 Seconds
2 Minutes
2 Minutes
3 Minutes
4 Minutes
UL installations: The Entry Delay must be set for a maximum of 45 seconds.
SIA: The Entry delay must be set to a minimum of 30 seconds. The sum of entry delay 1 and
the Alarm Report Delay (burglary abort window) should not exceed 1 minute. "None" is
only allowed for use in Commercial High-Security applications.
Select "Exit Delay". The System toggles between the following options:
LYNX Touch
LYNX Touch Canada
(L5200/L7000)
(L5200CN/L7000CN)
45 Seconds
None
60 Seconds
15 Seconds
90 Seconds
30 Seconds
2 Minutes
45 Seconds
60 Seconds
90 Seconds
2 Minutes
UL installations: Exit Delay must be set for a maximum of 60 seconds
SIA: The Exit Delay must be set to a minimum of 45 seconds.
LYNX Touch Installation and Setup Guide
Programming the Control
ACTION
Entry Delay 2
Backlight Timeout
Quick Exit
Restart Exit Time
Auto Stay Arming
Power-Up In Previous
Display Exit Time
Cross Zone 2
- 49 -