If using 5800 Series transmitters, do not the install batteries until you are ready to enroll them. After
enrolling the transmitter, the battery need not be removed (except in a high traffic environment). This is
to prevent enrolling the wrong serial number.
PROMPT
ZONE PROG?
1 = YES
0 = NO
0
SET TO CONFIRM?
1 = YES
0 = NO
0
ENTER ZONE NO.
000 = QUIT
010
Zone 010 entered
010 ZT P RC In L
0 0 1 1 0 0 0 1
010 ZONE TYPE
PERIMETER
03
Zone number 010 and
Zone Type 03 entry shown
† These are special zone
types used with 5800
Series Wireless Keys
Units that result in
arming the system in
the STAY or AWAY
mode, or disarming the
system, depending on
the selection made.
010 Arm w/ Fault?
1 = YES
0 = NO
0
g
g
EXPLANATION
Press 1 to enter ZONE PROGRAMMING mode. The following screens appear. Press [∗] to display the next
screen. Press # to display a previous screen.
This prompt appears once upon entering Zone Programming Mode.
If "Yes," Confirmation prompts will be displayed after the device's Serial and Loop numbers have been
entered later.
Enter the 3-digit zone number to be programmed, as follows:
• Protection Zones .................................... 001–250
• Relay Zones .............................................. 601–632
• ECP Device Supervisory Zones ...... 800–830
• System Supervisory Zones ............... 970 (bell supervision), 988, 990 (RF receiver), 992 (duress), 997
• Keypad Panic Zones ............................ 995, 996, 999
WHEN SUPERVISING THE BELL OUTPUT (ZONE 970), ONLY ONE DEVICE CAN BE
UL
CONNECTED TO THE ALARM OUTPUT (TERMINALS 4 AND 5) FOR UL AND FIRE
INSTALLATIONS.
Press [∗] to continue.
This display appears, showing a summary of the zone's current programming.
• ZT = Zone Type,
• P = Partition,
• RC = Report Code,
• In = The input type of device, and
• L
= The device's loop number to which the sensor is connected.
NOTES:
• Some devices can support more than one zone by means of individual loops (for example, 5834-4,
5816, 5817, etc.).
• If the zone is not programmed, the display appears as shown here.
• If you are checking a zone's programming, and it is programmed satisfactorily, press [#] to back up
one step and enter another zone number, if desired.
Press [∗] to continue.
Each zone must be assigned a zone type, which defines the way in which the system responds to faults
in that zone. Refer to the Zone Type Definition section. Enter the zone type desired (or change it, if
necessary). Available zone types are listed below.
NOTE: If changing a zone type, make sure you delete the previous zone and reprogram the entire
zone.
00 = Assign for Unused Zones
01 = Entry/Exit #1, Burglary
02 = Entry/Exit #2, Burglary
03 = Perimeter, Burglary
04 = Interior Follower, Burglary
05 = Trouble Day/Alarm Night
06 = 24 Hr. Silent Alarm
07 = 24 Hr. Audible Alarm
08 = 24 Hr. Auxiliary
09 = Fire Without Verification
10 = Interior Delay, Burglary
Press [∗] to continue.
If you selected response type 1, 2, 4, or 10, this prompt appears.
Enter 1 = to enable arming of the partition with this zone faulted.
NOTE: The zone must be restored (see Force Arming, the next prompt) before the exit delay expires
otherwise the system starts the entry delay and must be disarmed, or an alarm occurs.
(polling loop short)
12 = Not Used
14 = CO Detector Alarm
16 = Fire With Verification
20 = Arm–STAY†
21 = Arm AWAY†
22 = Disarm†
23 = No Alarm Response (e.g., relay activation)
27 = Access Point
28 = Not Used