LYNX Touch L7000 Series Control
Quick Installation Guide
This Quick Installation Guide can help you install the rechargeable LYNX Touch Series Control quickly and easily by providing the basic steps for installation using the built-in defaults.
FOR DOCUMENTATION AND ONLINE SUPPORT:
Guide P/N 800-16082 or higher.) A copy of the Installation and setup Guide may also be requested from Honeywell.
1. Install the Control
INSTALL
SCREW
IN CASE
TAMPER
CASE
ILP5
TAMPER
SPACER
DETAIL A
BATTERY
CABLE CHANNEL
BATTERY WIRE
ROUTING CLIPS (3)
MOUNTING
HOOKS
(HINGES)
COMMUNICATION
MODULE
RECEPTACLE
EDGE
CONNECTOR
TAMPER
SWITCH
TIE WRAP
POINTS (2)
LOCKING TABS
1. Release the front case from the rear case by depressing the two
locking tabs at the top of the unit with the blade of a medium size
screwdriver.
2. Separate the front and back case assemblies by rotating the front
case so that it is perpendicular to the rear case and unsnapping
(releasing) the two hooks (hinges) from the back case.
3. Feed the wiring through the appropriate openings in the back
case. Use tie wraps to secure the wiring to the built-in wire loops
as needed.
4. Mount the back case to a sturdy wall and secure with the provided
screws.
5. If required, install an additional mounting screw in the case
tamper (see Detail A).
6. Attach the front and back cases by connecting the hooks on the
front case to the attachments on back case. Once attached, the
hooks will support the front case and allow you to make the wiring
connections.
7. After all of the wiring connections have been made, snap the front
case and back case closed and ensure that the locking tabs
secure the case.
Ê800-16088V1lŠ
800-16088V1 11/17 Rev. A
http://www.security.honeywell.com/hsc/resources/MyWebTech
2. Make Wiring Connections
OBSERVE POLARITY WHEN CONNECTING
THE POWER SUPPLY TO THE TERMINAL STRIP.
TIE WRAP
POINT (2)
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
BACK
CASE
EARTH
GROUND
MOUNTING
HOLES (4)
POWER
RECEPTACLE
ROTATE
FRONT CASE
UPWARD
TO RELEASE
HOOKS
TERMINAL
STRIP
EDGE CONNECTOR
(L5200-ZWAVE-EU)
EDGE
CONNECTOR
WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM
FRONT
CASE
Note: For the complete Summary of Connections, refer to the LYNX
Touch Series Installation and Setup Guide P/N 800-16082 or
7000-100-031-V1
higher.
1. Make earth ground connections to EGND terminal.
2. Connect the sensors/contacts to the HWZ1 (+) and GND (-)
terminals.
3. If used, install the communications module Refer to the Install the
Communications Module section or to the Installation Guide for
the Communications Module.
4. Connect wires from the 300-04705V1, 300-04065V1 OR 300-
04063V1 (Canada) Power Supply to GND (-) and +9VDC (+)
terminals OR plug the Power Supply connector into the receptacle
on the LYNX Touch.
RF Exposure Warning
The antenna(s) used for this transmitter must be installed to
provide a separation distance of at least 7.8 in (20 cm) from all
persons and not co-located or operated in conjunction with any
other transmitter except in accordance with FCC multi-transmitter

product procedures.
Important Note
If an external cellular radio antenna is used, the antenna must be
installed or replaced ONLY by a professional installer.
(see LYNX Touch Series Installation and Setup
3. Install the Communications Module
NOTE
ETHERNET CABLE
THE 300-04705V1 OR
TO ILP5
300-04705V1-EUR IS
AVAILABLE FROM
HONEYWELL AND MUST
BE PROVIDED DURING
RJ45 RECEPTACLE
INSTALLATION
LYNX TOUCH
HARD
WIRED
ALTERNATE INSTALLATION
ZONE
300-04705V1 OR
300-04705V1-EUR
ILP5
2K
POWER SUPPLY
SPACER
OHM
9VDC, 2.5A
EOLR
RJ45
RECEPTACLE
CONNECTOR
BOARD
ROTATED
TIE
180
WRAP
(1)
ILP5
SIM CARD
CONNECTOR BOARD
CELLULAR
SCREW
COMMUNICATION
(3)
ZONES
POWER
MODULE
(3GL/3GLC SHOWN)
EDGE CONNECTOR
(L5100-WIFI-ME)
ROTATED
180
7000-100-040-V1
RECEPTACLE
CONNECTOR BOARD
LYNX TOUCH
Ensure that SIM card and the connector board are securely
installed in the communications module before installing it in
the LYNX Touch.
1. If you are installing the ILP5 module, use a wire cutter or knife to cut
the plastic tabs that secure the ILP5 spacer to the back case of the
LYNX Touch L7000. If you are installing a cellular communication
module, proceed to step 3.
2. Remove the ILP5 receptacle knockout from the left side of the
LYNX Touch back case
3 Install the Communications Module into the front case. Ensure that
the connector board is properly seated into the receptacle on the
control.
4 Secure the module with the three provided screws. If you are
installing the ILP5 module, proceed to step 5. If you are installing a
cellular communication module, proceed to step 8
5. Insert the ILP5 receptacle and spacer into the slot on the back
case.
6. Secure the communications cable to the tie wrap point on the ILP5
with the provided tie wrap.
7. Connect the Ethernet cable to the RJ45 receptacle.
8. Enable the module, configure alarm reporting and module
supervision and register the device. Refer to the "Communications
Diagnostics" section of the LYNX Touch L7000 Installation Guide
(P/N 800-16082 or higher).
For the latest warranty information, please go to:
4. Make Battery Connections
NOTE:
SIM CARD INSTALLED
IN 3GL/3GLC ONLY
RETAINER
BATTERY PACK
(P/N 300-03864-1/
LYNXRCHKIT-SC)
REMOVE
REMOVE
ILP5
ILP5
KNOCKOUT
SPACER
TIE
WRAP
POINT
7000-100-032-V2
1. Insert battery pack into back case.
2. Install battery retainer.
3. Install screw to secure the battery retainer.
4. Connect battery connector to receptacle on PC board.
5. After all wiring connections have been made, snap the front case
to the back case so it is held by the locking tabs.
6. Plug the Power Supply into a 24-hour, 110VAC unswitched outlet.
Note: Rechargeable batteries may take up to 48-hours to fully
charge. "Battery Low" message should clear within four hours,
or by entering Test Mode.
Battery
Part Number
LYNXRCHKIT-SC
(300-03864-1)
LYNXRCHKIT-SHA
(300-03866)
WARRANTY INFORMATION
www.honeywell.com/security/hsc/resources/wa
SCREW
SCREW
RETAINER
BATTERY PACK
(P/N 300-03866/
LYNXRCHKIT-SHA)
OR
7000-100-029-V0
Battery Standby
Low Battery Notification
Time (Minimum)
Approx. 1-hour before
4-hours
battery depletion
At least 1-hour before
24-hours
battery depletion
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2017 Honeywell International Inc.
www.honeywell.com/security

Advertisement

loading

Summary of Contents for Honeywell LYNX Touch L7000 Series

  • Page 1 (see LYNX Touch Series Installation and Setup http://www.security.honeywell.com/hsc/resources/MyWebTech www.honeywell.com/security/hsc/resources/wa Guide P/N 800-16082 or higher.) A copy of the Installation and setup Guide may also be requested from Honeywell. 1. Install the Control 2. Make Wiring Connections 3. Install the Communications Module 4.
  • Page 2 Report All 4. Enter a new 4-digit User Code. higher for additional information) Note: Refer to the Lynx Touch L7000 Series User Guide P/N 800- Report Alarms 5. Select “Done”. 16084 or higher for additional information. Change/Edit Users or User Codes...