installinG thE housinG assEMBlY:

Be sure the bracket is properly and securely mounted
!
to a supporting structure capable of rigidly holding
the weight of the entire unit.
notE: This unit is designed for operation in an
upright position. Installing the housing
upside down may cause damage to
the internal equipment, and will void the
warranty.
installinG PEnDant Mount
1. This unit includes a 1½" NPT housing for a standard 1½"
NPT pipe. The housing can be used with other brackets
designed with 1½" male pipe threads, such as the WM20G
wall mount bracket.
2. Attach the housing coupling.
notE: Pipe threads should be clean and rust-
free. Use the Teflon
the housing on the threads.
A small roll of Teflon tape is provided with all pendant units.
tape included with
Add thread
sealing tape
Teflon Tape
- 6 -
3. Mount the housing assembly to the mounting bracket
and housing coupling. A safety cable is included with
the housing to temporarily hold it while making wiring
connections. Loop the safety cable over one of the set
screws on the housing coupling and make the appropriate
connections using the (2) screw-down connectors supplied.
4. Undo the safety cable and twist the housing onto the
housing coupling. Secure all (3) setscrews provided on the
housing coupling.
Set screws
installinG Wall Mount
A wall mount bracket comes standard with this unit, and
a template is included to use as a guide for mounting the
bracKet to a wall.
1. Choose the desired location for installation and mark
the drill holes using the template. Screw (2) bolts (not
provided) about ¾ of the way into the (2) top holes. Run
approximately 8 of wiring out of the wall.
notE: Be sure the hardware and the mounting
surface can support the weight of the
wall mount bracket plus the weight of the
housing and drive unit. The load will be
subjected to vibration from the camera
motor and wind.
2. The wall mount bracket provided with the FDW7 includes
a location for conduit entry. If you wish to install conduit to
the bracket remove the conduit hole plug. Install fitting from
below the wall mount and secure with conduit nut from
inside the bracket.