Chapter 1 Introduction
Command-Line Interface (CLI)
The CLI allows you to use text-based commands to configure the ZyWALL. Access it using remote
management (for example, SSH or Telnet) or via the physical or Web Configurator console port.
See the Command Reference Guide for CLI details. The default settings for the console port are:
Table 2 Console Port Default Settings
SETTING
Speed
Data Bits
Parity
Stop Bit
Flow Control
1.3 Web Configurator
In order to use the Web Configurator, you must:
• Use one of the following web browser versions or later: Internet Explorer 7, Firefox 3.5, Chrome
9.0
• Allow pop-up windows (blocked by default in Windows XP Service Pack 2)
• Enable JavaScripts, Java permissions, and cookies
The recommended screen resolution is 1024 x 768 pixels.
1.3.1 Web Configurator Access
Make sure your ZyWALL hardware is properly connected. See the Quick Start Guide.
1
In your browser go to http://192.168.1.1. By default, the ZyWALL automatically routes this request
2
to its HTTPS server, and it is recommended to keep this setting. The Login screen appears.
Type the user name (default: "admin") and password (default: "1234").
3
If you have a OTP (One-Time Password) token generate a number and enter it in the One-Time
Password field. The number is only good for one login. You must use the token to generate a new
number the next time you log in.
20
VALUE
115200 bps
8
None
1
Off