Remove Connecting Rods With Pistons And Rings - Kohler Courage SV710-740 Service Manual

Vertical crankshaft
Hide thumbs Also See for Courage SV710-740:
Table of Contents

Advertisement

Figure 8-47. Removing Governor Cross Shaft
Retainer.
2. Remove the cross shaft with the small inner
washer through the inside of the crankcase. See
Figure 8-48.
Governor
Shaft
Washer
Figure 8-48. Removing Governor Cross Shaft.
3. Remove the governor shaft seal from the
crankcase.
Retainer
Washer
Remove Connecting Rods with Pistons
and Rings
1. Remove the two hex flange screws securing the
closest connecting rod end cap. Remove the end
cap. See Figure 8-49.
Figure 8-49. Removing Connecting Rod End Cap.
NOTE: If a carbon ridge is present at the top of
either cylinder bore, use a ridge reamer
tool to remove it before attempting to
remove the piston.
2. Carefully remove the connecting rod and piston
assembly from the cylinder bore. See Figure 8-50.
NOTE: The cylinders are numbered on the
crankcase. Use the numbers to mark
each end cap, connecting rod and piston
for reassembly. Do not mix end caps and
connecting rods.
Figure 8-50. Removing Connecting Rod and Piston
Assembly.
3. Repeat the above procedure for the other
connecting rod and piston assembly.
Section 8