NOTE: If the wires were disconnected from
the ignition modules on engines with
DSAM, reattach the leads and seal the
base of the terminal connectors with GE/
Novaguard G661 (Kohler Part No. 25
357 11-S) or Fel-Pro Lubri-Sel dielectric
compound. The beads should overlap
between the terminals to form a solid
bridge of compound. See Figures 10-60
and 10-62. Do not put any compound
inside the terminals.
2. Connect the kill lead to the tab terminal on
standard ignition modules. See Figure 10-61.
1. Install the B+ terminal/lead into the center
position of the rectifier-regulator plug so it locks
in place, and connect the plug to the rectifier-
regulator. See Figure 10-63.
2. Attach the rectifier-regulator to the opening in
backing plate from the underside, and secure
with the two mounting screws. See Figure 10-64.