3. Plug the tester into a 110 volt AC outlet and
turn on the power switch. See Figure 7-23. The
POWER light should be illuminated and one of
the four status lights may be on as well. This does
not represent the condition of the part.
4. Press the TEST button until a click is heard and
then release. See Figure 7-24. Momentarily one of
the four status lights will illuminate, indicating
the condition of the part.
a. If the OK (green) light comes on and stays
steady, the part is good and may be used.
b. If any other light is displayed,* the rectifier-
regulator is faulty and should not be used.
*NOTE: A flashing LOW light can also occur as
a result of an inadequate ground lead
connection. Make certain connection location
is clean and clamp is secure.
1. Connect the single lead adapter in between the B+
(center) terminal of the rectifier-regulator being
tested and the squared single end of the tandem
adapter lead. See Figure 7-25.
2. Connect the tester ground lead (with spring
clamp) to the body of the rectifier-regulator.
3. Connect the red lead and one of the black leads
to the pair of terminals on the open end of
the tandem adapter lead (connections are not
location specific).
4. Connect the remaining black lead from the tester
to one of the outer AC terminals on the rectifier-
regulator. See Figure 7-26.
5. Plug the tester into a 110 volt AC outlet and turn
on the power switch. The POWER light should
be illuminated and one of the four status lights
may be on as well. See Figure 7-23. This does not
represent the condition of the part.