5. Connect the breather hose to the air cleaner base
and secure with the clamp. See Figure 10-73.
6. Move the governor lever toward the carburetor as
far as it will go (wide-open throttle), and hold in
position.
7. Insert a nail or similar tool into the hole on the
cross shaft and rotate the shaft counterclockwise
as far as will turn, then torque the hex nut to
6.8 N·m (60 in. lb.). See Figure 10-74.
1. Install the air cleaner element (with precleaner if
equipped), onto the air cleaner base. Secure with
the latch. See Figure 10-75.