2. Invert the breather housing (cover) and apply
a 1.5 mm (1/16 in.) bead of RTV sealant to the
perimeter flange of the outer housing (cover) as
shown in Figure 10-29. Use Loctite
Kohler Part No. 25 597 07-S.
3. Immediately install the housing over the
mounting stud and onto crankcase. Do not allow
the RTV sealant to come in contact with the
breather reed, or the reed sealing surface.
4. Secure with a new sealing washer and the M5 hex
nut. Torque the hex nut to 1.3 N·m (12 in. lb.).
Check that a complete seal has occurred by the
RTV sealant being squeezed out around the
entire flange perimeter. See Figure 10-30.
5. Attach the breather hose to the housing if
disconnected earlier. Make sure the cover is
between the formed lips of the breather hose.
®
5900 or 5910,
Position the hose so the opposite end is away
from the crankshaft. See Figure 10-31.
NOTE: The RTV sealant should be allowed to cure
1. Apply pipe sealant with Teflon
59241 or equivalent) to the stator mounting holes.
2. Position the stator aligning the mounting holes
so that the leads are at the bottom, toward the
crankcase.
3. Install and torque the two hex flange screws to
6.2 N·m (55 in. lb.). See Figure 10-32.