2.3 Precautions on Installation
Read the following notes before starting OS installation.
2.3.1 Installation Partition Size
For installation using ServerStart, the installation partition size can be set as follows.
• Maximum size: 2TB
• Minimum size: 2200MB
●
Notes
• When you want to set the OS and BOOT partitions in different partitions, specify the partition size
directly.
• In either of the following cases, specify a partition size up to 2TB.
• When the same partition is specified as the OS and BOOT partitions
• When different partitions are specified as the OS and BOOT partitions
• The OS cannot be installed in a partition larger than 2TB.
The BOOT partition is a partition for booting. Minimum information that is necessary for booting such
as "ntldr" is set.
The OS partition is a partition for installing the OS.
2.3.2 Notes on Configuring RAID
RAID can be configured with hard disk units connected to the SAS controller on the baseboard.
For available RAID level, configuration of RAID and cautions, refer to "Integrated Mirroring SAS
User's Guide" in the Array Controller Document & Tool CD.
●
Hardware configuration
• Only internal hard disk units can be used.
• Be sure to use hard disk units of the same model and with the same capacity.
●
When RAID-configured hard disk unit is used
Hard disk units that have been used before may have unwanted partition information or array
configuration information, which may cause unexpected problems. If you connect any hard disk units
with usage history to this server, format them at low level on another system before connecting them to
the server. For information on how to format the hard disk, refer to the manual of the system to be used.
PRIMERGY BX620 S4 Server Blade User's Guide
39