Management Blade (monitoring device)
This blade is used to monitor the power supply, fan, and temperature in each blade and the Chassis.
It is equipped with a dedicated CPU, LAN, and serial ports. This blade is independent of the Server
Blade, ensuring stable system operation.
The Management Blade also enables you to remotely control and monitor each blade from a
management terminal via a LAN or serial port.
[Front]
[Rear]
Switch Blade/GbE Pass-Thru Blade, etc.

■ High reliability

Redundant function
This server enables a redundant configuration for fan, power supply unit (optional), and Management
Blade.
The Management Blade supports the standard redundant configuration in which one unit manages the
entire system in the master mode and another one is on standby in the slave mode. In this configuration,
if the master Management Blade causes a failure, the slave blade takes over management without
interrupting system operations.