3
5
Check a distance (a) and distance (b) on the output sheet.
6
If the desired result cannot be obtained, touch [ADJUSTMENT] tab.
The Tri-Fold Position Adjustment Screen will be restored.
7
Touch the required size key.
8
Touch [Double Fold].
9
Use the touch panel keypad to enter the desired adjustment value, then touch [<<SET].
Available range: -50 to +50, 1 step = 0.1 mm
The distance (a) in step 5 will increase when the "+" value is entered, and decrease when the "-"
value is entered.
10
Touch [Single Fold], then repeat step 9.
The distance (b) in step 5 will increase when the "+" value is entered, and decrease when the "-"
value is entered.
11
Repeat steps 3 to 10 until the desired result is obtained.
12
If adjustment in any other size is required, repeat steps 3 to 11.
13
Touch [Return] to restore the Adjustment Menu Screen.
3-58
a
[2]
[1]
b
Adjustment
CS665 Pro