11.1 Error Messages (EXXXX)
Error Code
E1007
You have exceeded the system limit of remote cards.
One ERMT card can be installed in the system -- only one.
E1008
You have exceeded the system limit of DPH cards.
There is a limit of two DPH cards per system.
E1010
You must change card type to None, before changing to new card type.
This process to make sure all data for previous card is deleted.
E1011
The card of clock configuration priority duplicated.
Each card must have a unique priority.
E1012
The status of the card is not INS (In-Service).
To use this port, you must put the card INS (In-Service).
When the card is INS (In-Service) status, all the ports of the card become in service.
E1013
Cannot change the attribute of the port which is the paired extension of a DSS
console.
The attribute of this port cannot be changed until it is de-assigned as the paired
extension of a DSS console. Please change the attribute after de-assignment.
E1014
You have exceeded the system limit of DSS consoles.
There is a limit of 64 consoles per system.
E1015
Incomplete directory number.
The DN and FDN must be 3 or 4 digits.
E1016
Invalid directory number.
The entered DN doesn't match the numbering plan in "2-2 Numbering Plan" screen.
E1017
Directory number already exists.
The entered DN or FDN already exists.
E1018
Directory number doesn't exist.
The entered DN doesn't exist.
E1019
Invalid directory number for paired extension of DSS console.
Only the DN of PT can be assigned as the DN for the paired extension of a DSS
console.
E1020
You have exceeded the limit of DSS consoles per PT.
There is a limit of 8 DSS consoles per PT.
E1022
Assign the directory number before making the port INS (In-Service) status.
An extension without a DN cannot be placed into service.
E1023
Assign the directory numbers for EXT#1 and EXT#2.
For the VPS port you must assign directory numbers for both voice mail numbers,
EXT#1 and EXT#2. These cannot be assigned individually.
E1024
Cannot assign the port which does not have VPS (DPT) attribute.
To be used as a VPS port, this port must have the VPS (DPT) attribute in "1-3 Extension
Port Assignment" screen.
272
Error Message
Description
Programming Error Messages